Software version 6.2.0 introduced a feature to verify the integrity of the firmware by validating its signature. If the signature is valid, the firmware will be installed. If the signature is invalid, the firmware will not be installed.If a device is running version 6.2.0 software (or later) and you wish to install a version prior to 6.2.0 (which does not contain a signature), the “Install” and “Validate” buttons will result in a failure of the validation, since there is no signature.
This issue may affect any MSM product that supports MSM software version 6.2.0: J9374A, J9379A, J9380A, J9383A , J9360A, J9364A, J9365A, J9368A, J9369A, J9373A, J9358A, J9359A, J9356A, J9357A, J9426A, J9427A, J9524A, J9527A, J9528A, J9529A, J9530A, J9358B, J9359B, J9530B, J9360B, J9364B, J9527B, J9365B, J9368B, J9528B, J9374B, J9379B, J9524B, J9380B, J9383B, J9369B, J9373B, J9356B, J9357B, J9426B, J9427B, J9529B, J9590A, J9591A, J9618A, J9655A, J9621A, J9622A, J9656A, J9650A, J9651A, J9653A, J9654A, J9693A, J9694A, J9695A, J9696A, J9397A, J9398A, J9421A, J9420A, J9370A, JG653A, JG654A, JG655A, JG656A, J9423A, J9422A
If version 6.2.0 software (or later) is running on your MSM device and you wish to downgrade to a version that is earlier than version 6.2.0, you should use the “Force install” button in the GUI to perform the installation. This will skip the signature validation step and install the software.
Operating Systems Affected:Not Applicable