Revision TableVersionDateDetailsVersion 2Updated the Resolution sectionVersion 113 December 2013Original document releaseA timing-dependent condition has been encountered when performing an online controller replacement on an HP P2000 G3 MSA array.If the controller is partially inserted, the controller will connect to the backplane and will start the boot-up process. Depending on the timing between the initial insertion and when the thumb screws are tightened, the controller may make and break electrical contact with the backplane, causing a second boot sequence to be triggered in some rare situations, which could result in a virtual disk (Vdisk) becoming unusable. This advisory documents two procedures, either of which can be used to work around this situation so that the controller replacement can be performed successfully and without causing any impact to production.
This issue affects HP P2000 G3 MSA Array Systems on any firmware version of TS250 or earlier.
This issue was corrected in TS251R004 HP P2000 G3 MSA array firmware. A replacement or spare controller might have an earlier version of firmware. If replacing a controller, the controller should be inserted such that it fully contacts the backplane, after which the thumb screws should be immediately tightened.WorkaroundIf there is a need to replace a controller in an HP P2000 G3 MSA array while the system is running, the controller should be inserted such that it fully contacts the backplane, after which the thumb screws should be immediately tightened.Follow either of the below workaround steps to mitigate the risk of hitting this issue:Workaround 1Moving all Vdisks to the currently active controller prior to replacing a failed controller will avoid this issue during the controller replacement.Before moving a Vdisk to the opposite controller, be sure to halt all host I/O.Navigate through the following options:SMU > Configuration View > Select Vdisk > Configuration > Modify Vdisk Owner > Vdisk Owner > A|B > Modify Owner.Execute the following CLI command:# set vdisk owner a|bShut down the controller which needs to be replaced. Make sure the replacement controller is firmly seated and the thumb screws are fully tightened.Reconnect all network and host cables.After inserting the new controller, verify the firmware versions of the controllers are the same. Inserting a new controller may cause a firmware upgrade to occur.Before moving the Vdisks ownership back to the new controller, allow all firmware upgrades to fully complete.Workaround 2Schedule a maintenance window where both controllers may be properly shut down. With no I/O occurring to the array, properly shut down the array.Navigate through the following options:SMU > Tools > Shut Down or Restart Controller > Operation: Shut down > Controller type: Storage > Controller: Both > Shut down now.Execute the following CLI command:# shutdown bothOnce the controllers are properly shut down, replace the failed controller. Make sure the replacement controller is firmly seated and the thumb screws are fully tightened.Reconnect all network and host cables.Power back on the array.Once the controllers are powered back on, check the firmware versions, user profiles, network addresses, alert settings, and any unique configuration settings.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.