Takeover-recovery (resync) operation for a copy pair of the HP XP P9000 Continuous Access Journal copy type may fail with the RPM-03304 message.This issue occurs when all of the following conditions are met:A copy pair of the XP P9000/XP Continuous Access Journal copy type exists.The copy pair is configured on one or more of the following storage systems:HP XP P9500XP24000/XP20000You select the copy pair, start the Change Pair Status Wizard, and then executetakeover-recovery(resync).
HP XP P9000 Replication Manager Software is affected by this advisory.
These issues will be addressed in a future version of HP XP P9000 Replication Manager Software.WorkaroundOn the pair management server of the secondary site, execute the XP P9000 RAID Manager command,pairresync with -swaps option.
Operating Systems Affected:Not Applicable