Revision TableVersionDateDetails28 November 2013Deleted sentences regarding removal of Smart Array from website, correcting the Smart Array, and the issue currently being under investigation.115 October 2013Original document release.HP D2200sb PCIe Storage Blades are partnered with HP BladeSystem server blades to provide Direct-Attached-Storage (DAS). The HP Service Pack for ProLiant is used to upgrade HP BladeSystem server blades. The HP Service Pack for ProLiant also upgrades the firmware on various components of the D2200sb Storage Blade when the partnered server blade is upgraded.An issue has been identified with the Smart Array P410i Smart Component that is available on the HP Service Pack for ProLiant 2013.09.0(B). In some cases, this smart component will update the SAS expander in the D2200sb with incorrect firmware.This issue will cause the Smart Array P410i Controller to be unable to communicate with the hard drives installed in the D2200sb, and thus the logical drives on the storage blade will be unavailable to the partnered server blade.A force flash of the following components within the HP Service Pack for ProLiant 2013.09.0(B) will disable the P410i controller:CP020865.exeOnline ROM Flash Component for Windows - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40CP020864.scexeSupplemental Update/Online ROM Flash Component for Linux - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40CP020863.scexeOnline ROM Flash Component for VMware ESXi - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40If the Smart Array P410i Controller is currently running a version of firmware prior to 6.0, and SPP Version 2013.09.0(B) is used to perform an automated update, the Smart Array P410i Controller will be updated to version 6.40 and the controller will become disabled.This issue willnotoccur if the Smart Array P410i Controller is running firmware version 6.0 at the time of the SPP Version 2013.09.0(B) update.
Products affected by this advisory are HP D2200sb PCIe Storage Blades.
Do not use HP Service Pack for ProLiant Version 2013.09.0(B) to update the P410i Smart Array Controller on a blade server when the server is attached to a D2200sb Storage Blade. Please ensure the following Smart Components arenotselected in this configuration:CP020865.exeOnline ROM Flash Component for Windows - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40CP020864.scexeSupplemental Update/Online ROM Flash Component for Linux - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40CP020863.scexeOnline ROM Flash Component for VMware ESXi - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812 version 6.40The HP website has been updated to include the correct Smart Array P410i Smart Components, version 6.40(B).If you performed a Smart Array P410i Controller firmware update as described above, and you lost access to a partnered D2200sb storage blade, the only resolution is to replace the drive drawer assembly, part number 621523-001.To start the repair, call HP Support as follows:In North America, contact Customer Support at 1-800-334-5144.ORFor Customer Support outside of North America, click on the following URL for a list of Customer Support Centers and appropriate phone numbers:https://support.hpe.com/hpesc/public/home
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.