Document VersionRelease DateDetails311/12/2013Modified the steps underLocating the Firmware - ProLiant and StoreVirtual Systemsin the Resolution for HP P2000 G3 Modular Smart Array Systems.210/31/2013Added SAS hard drive model EG1200FCVBQ to the Scope and Resolution.109/09/2013Original Document Release.IMPORTANT: The hard drive firmware updates in the Resolution section below are considered a critical fix and are required to prevent the issue detailed below. HP strongly recommends immediate application of this critical fix. Neglecting to perform the required action could leave the server in an unstable condition, which could potentially cause stale data to be written to the drive, resulting in data corruption. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.The specific HP SAS hard drive models listed in the Scope section (below) could potentially encounter a rare data miscompare issue that can lead to stale (out of date) data being written to the drive, which can result in unexpected data being returned during subsequent read requests.IMPORTANT:This issue has only been observed in a lab environment under firmware stress test conditions, and has not been reported to date in a customer environment.
Any HP server or storage system configured with any of the following HP SAS drive models running an affected version of the drive firmware, as listed in Table 1 below:Note: The Option Kits listed in Table 1 do not necessarily contain affected drive models. Multiple Option Kit numbers may be used for each drive model, and multiple drive models may be used for each Option Kit. Only the drive models themselves are affected by this issue.Drive ModelDrive DescriptionOption KitNumberAffectedFirmwareVersionEG0300FBVFLHP 300GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive574879-B21652564-B21Earlier thanHPD9EG0450FBVFMHP 450GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive652572-B21Earlier thanHPD9EG0600FBVFPHP 600GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive642114-B21652583-B21Earlier thanHPD9EG0900FBVFQHP 900GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive652589-B21619291-B21Earlier thanHPD9EG1200FCVBQHP 1.2TB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive693648-B21697572-B21697574-B21Earlier thanHPD6MB2000FBUCLHP 2TB 6Gb/sec SAS 7.2K RPM 3.5-inch (LFF) Hard Drive652757-B21507616-B21Earlier thanHPDAMB3000FBUCNHP 3TB 6Gb/sec SAS 7.2K RPM 3.5-inch (LFF) Hard Drive652766-B21QR479AEarlier thanHPDATable 1: Affected HP SAS Hard Drive Models and Firmware Versions
To ensure that stale data is not written to the drive due to this issue, upgrade to the appropriate HP SAS hard drive firmware version, as listed in Table 2 below, which can be located for download using the navigation steps that follow:Drive ModelDrive DescriptionOption KitNumberCorrectFirmwareVersionEG0300FBVFLHP 300GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive574879-B21652564-B21HPD9 orLaterEG0450FBVFMHP 450GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive652572-B21HPD9 orLaterEG0600FBVFPHP 600GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive642114-B21652583-B21HPD9 orLaterEG0900FBVFQHP 900GB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive652589-B21619291-B21HPD9 orLaterEG1200FCVBQHP 1.2TB 6Gb/sec SAS 10K RPM 2.5-inch (SFF) Hard Drive693648-B21697572-B21697574-B21HPD6 orLaterMB2000FBUCLHP 2TB 6Gb/sec SAS 7.2K RPM 3.5-inch (LFF) Hard Drive652757-B21507616-B21HPDA orLaterMB3000FBUCNHP 3TB 6Gb/sec SAS 7.2K RPM 3.5-inch (LFF) Hard Drive652766-B21QR479AHPDA orLaterTable 2: Corrected HP SAS Hard Drive Models and Firmware VersionsLocating the Firmware - ProLiant and StoreVirtual SystemsGo tohttp://www8.hp.com/us/en/drivers.htmlFor HP ProLiant and HP Storage systems, enter the drive model (for example, "EG0300FBVFL") for the product and clickSearch.For HP StoreVirtual 4000 Storage, HP D2000 disk enclosures, and HP D2700 backup systems, enter the model of the system and clickSearch.For HP P2000 G3 Modular Smart Array Systems, go to the following link:http://h20566.www2.hp.com/portal/site/hpsc/public/psi/swdHome/?cc=us&cc=us&lang=en&lang=en&sp4ts.oid=5174868&ac.admitted=1383343042108.876444892.199480143Select the appropriate operating system.SelectFirmware -SAS Storage Disk.Download and install the latest version of the firmware.Reboot the system to complete the upgrade.Locating the Firmware - Integrity SystemsGo tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software.For HP Integrity systems, enter the drive model (for example, "EG0300FBVFL") for the product and clickSearch.Select the appropriate operating system.Select the current version (for example,"Hard Disk Drive Firmware Release for HP Integrity Diagnostics - G0300FAWJD_EG0146FAWJC_DG0300FARVV_DG0146FARVU_DG0300BAMYR_DG0146BAMYQ" - Version HPDG 25 Apr 2013).Download theRelease Notesfor installation details.Note:The Integrity offline tool, referred to asODE + DFDUTIL, may be downloaded under theDiagnosticcategory for the Integrity Server in use.Locating the Firmware - Other HP SystemsGo tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software.Enter the model of the system and clickSearch.Select the appropriate operating system.SelectFirmware -SAS Storage Disk.Download and install the latest version of the firmware.Reboot the system to complete the upgrade.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to HP SAS hard drives, use the following search string:+Advisory -"Software and Drivers" +HP +"SAS Hard Drive"
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.