After a File Serving Node (FSN) in an HP StoreAll cluster has accumulated more than 497 days of uptime, the file system will no longer be accessible from that node. If that file system is mounted on more than one node, and the other nodes have not reached the 497 day threshold, the file system will still be accessible from the other nodes.
This issue is seen in all HP StoreAll software versions.
Depending on the protocols in use and the length of the failover process, some protocols may reach their timeout threshold prior to the completion of the failover process. This could result in interrupted access to the file system accessed through that Virtual Interface (VIF) or incomplete copy jobs that may need to be restarted after this process is complete. It is best to follow this process during periods of low cluster utilization to minimize end user impact.This issue can be resolved by restarting the FSN prior to the 497 day mark. Refer to the following steps to restart the FSN prior to reaching the 497 day threshold minimally:Fail the FSN over to its backup so that access to the file system is not interrupted or interrupted minimally:ibrix_server -f -h <FSN_Name>Example =ibrix_server -f -h node1Restart the FSN:ibrix_server -P reset -h <FSN_Name>Example =ibrix_server -P reset -h node1Fail the FSN back from its backup:ibrix_server -f -U -h <FSN_Name>Example =ibrix_server -f -U -h node1In a future release of HP Store All Software scheduled to be released in late 2013, HP has implemented a notification in the form of an alert and file system state change at the 400 day mark to notify customers that the FSN should be rebooted prior to 497 days of uptime.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.