Loading...
Loading...
If a mainframe host has been registered as a pair management server in any of [Sites] listed in Sites in [Shared Views] and you then select one or more volumes managed by Device Manager and then open the Pair Configuration Wizard, followed by the Create Group dialog box, the Create Group dialog may not open, the KAVN00209-E message is displayed, and a copy group cannot be created.Symptoms:KAVN00209-EAn error that stopped processing occurred.(cause = java.lang.StringIndexOutOfBoundsException: String index out of range: 14)Conditions of occurrenceThis issue occurs when all of the following conditions are met:A mainframe host is registered as a pair management server in any of the Sites listed inShared Views.Select one or more volumes managed by Device Manager withUnpairedin the Host or Storage System View, and then open thePair Configuration Wizard.ClickCreate Groupin the Group Management window.
Models affected:HP XP P9000 Replication Manager 7.3.0-00 to earlier than 7.5.0-00Operating system affected:Windows, Linux
Upgrade HP XP P9000 Replication Manager to 7.5.0-00 or a later version so that the copy pair operation can be executed normally in the Pair Configuration Wizard.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.