Loading...
Loading...
Revision TableVersionDateDetails215 October 2012Revised model NB2000DBZPN upgrade to HP03 in the Resolution section13 October 2012Original releaseFATA disk drives of the models listed in the Scope section on HP 4000/6000/8000 Enterprise Virtual Arrays (EVAs), HP 4100/6100/8100 EVAs, and HP 4400/6400/8400 EVAs may fail due to the drive heads landing on areas of the disk containing data during a planned shutdown or power loss. These disk drives are more likely to experience this issue when they have been running for an extended period of time, potentially causing unrecoverable read errors or mechanical damage.NOTE: This issue has a higher probability of occurrence on arrays that run continuously and are rarely shut down or restarted.
This issue may occur with the following list of FATA disk drive models, which are supported in HP 4000/6000/8000 EVAs, HP 4100/6100/8100 EVAs and 4400/6400/8400 EVAs.1 TB 7200 RPM FATA Disk Drive, model NB1000DBZPL2 TB 7200 RPM FATA Disk Drive, model NB2000DBZPN2 TB 7200 RPM FATA Disk Drive, model NB2000DAMYV
To ensure that data loss or drive damage does not occur due to this issue, upgrade FATA disk drive firmware to the version listed as follows:Model NB1000DBZPL, upgrade to HP03Model NB2000DBZPN, upgrade to HP03Model NB2000DAMYV, upgrade to HP04NOTE: HP recommends that updated disk drive firmware on these affected models be installed five days prior to any planned power off shutdown of the array.NOTE: Due to the potential for data loss and mechanical damage, HP recommends that this firmware upgrade be installed as soon as possible. The minimum-supported firmware for the affected models listed in the Scope section have been set to these new firmware versions.Downloading disk drive firmware:Download the disk drive firmware bundled image and installation instructions from the following website:www.hp.com/support/evadiskfirmwareFor the 4000/6000/8000 EVA, 4100/6100/8100 EVA and 4400/6400/8400 EVA product series, select theHP EVA FC Hard Disk Drive Firmware Bundle, and then clickDownload.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.