After configuring an HP SAS Expander with an HP Smart Array P410/P410i Controller (which was previously connected to the internal backplane) on an HP ProLiant server, resetting the server may result in a1783 errormessage during Power-On Self-Test (POST).
Any HP ProLiant server configured with an HP Smart Array P410/P410i Controller (running Smart Array Controller Firmware Version 5.06, 5.12, or 5.14) that was previously connected to the internal backplane and then later attached to a newly installed HP SAS Expander.
To avoid the 1783 POST errors that can occur after installing an HP SAS Expander, upgrade to Smart Array Controller Firmware Version 5.70 (or later), which can be located for download using the following navigation:Go tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software(if this screen appears).Enter the controller model as "Smart Array P410."Select the specific product on the following screen.Select the appropriate operating system.SelectFirmware - Storage Controller.Download and install * RECOMMENDED * Online ROM Flash Component - Smart Array P212, P410, P410i, P411, P711m, P712m, and P812Firmware Version 5.70 (or later).Reboot the server to complete the installation.This firmware upgrade is also available on the Service Pack for ProLiant (SPP) Version 2012.06.0 (B), which is available at the following URL:HP Service Pack for ProLiant Downloadwww.hp.com/go/spp/downloadNote:On the SPP website, selectCurrent Versionand then download SPP Version 2012.06.0 (B) or later.Until Smart Array Controller Firmware Version 5.70 can be applied, perform the following to avoid the 1783 POST error condition:Power the server off.Disconnect one or both SAS cables connecting the Smart Array P410/P410i Controller and SAS Expander. As a precaution, ensure that the connectors on the loose ends of the cables are restrained or covered to prevent contact with any components.Power the server on and allow the server to complete the POST process.Power the server off and reconnect the SAS cables between the Smart Array P410/P410i Controller and SAS Expander.Power the server on. The server should operate normally at this point.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to SAS Expanders used with Smart Array Controllers, use the following search string:+Advisory +ProLiant -"Software and Drivers" +"Smart Array" +"SAS Expander"
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.