IMPORTANT: The HP SAS hard drive firmware upgrades listed in the Resolution are considered critical fixes and required to ensure that unexpected (older) data is not written to the drive cache on the specific HP SAS hard drive models listed in the Scope section below. HP strongly recommends immediate application of these critical fixes. Neglecting to perform the required action could leave the server susceptible to unexpected data being written to the drive cache. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.The specific HP SAS hard drive models listed in the Scope section (below) may, on rare occasions, encounter unexpected data being written to the drive cache in the following configuration:The drive is running an affected firmware version (or earlier) as listed in the Scope section below.Drive Write Cache (DWC) was enabled on the drive by the administrator. HP does not ship drives with DWC enabled.When this occurs, there is no indication of the problem.Note:This is a rare issue, which has not been reported in an HP customer environment. It was discovered in an HP lab environment during rigorous stress testing.
Any of the following HP SAS hard drive models configured with the following firmware versions and with Drive Write Cache enabled:Drive ModelDescriptionAffectedFirmwareDG0146BAMYQHP 146GB 3Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Non-Hot Plug Hard DriveHPDCDG0146FARVUHP 146GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPDCDG0300BAMYRHP 300GB 3Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPDCDG0300FARVVHP 300GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPDCEF0300FATFDHP 300GB 6Gb/sec SAS 15K rpm 3.5-inch (LFF) Dual-Port Hot-Plug Hard DriveHPD7EF0450FATFEHP 450GB 6Gb/sec SAS 15K rpm 3.5-inch (LFF) Dual-Port Hot-Plug Hard DriveHPD7EF0600FATFFHP 600GB 6Gb/sec SAS 15K rpm 2.5-inch (SFF) Dual-Port Non-Hot Plug Hard DriveHPD7EG0146FAWJCHP 146GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPDCEG0300FAWJDHP 300GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPDCEG0300FBDBRHP 300GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPD6EG0450FBDBTHP 450GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPD6EG0600FBDBUHP 600GB 6Gb/sec SAS 10K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPD6EH0072FARWCHP 72GB 6Gb/sec SAS 15K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPD9EH0146FARWDHP 146GB 6Gb/sec SAS 15K rpm 2.5-inch (SFF) Dual-Port Hot-Plug Hard DriveHPD9Table 1: Affected HP SAS Hard Drive Models and Firmware VersionsTo determine whether the above drive models are configured in the system, use any of the following HP utilities:HP Array Configuration UtilityHP Array Diagnostic UtilityHP Insight DiagnosticsHP Systems Insight Manager (HP SIM)HP System Management Homepage (SMH)
To ensure that unexpected data is not written to the drive cache, upgrade to the SAS drive firmware versions listed in Table 2 below (or later), which can be located for download using the following navigation:Go tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software.For HP ProLiant and Storage systems, enter the drive model (for example, "DG0146BAMYQ") for the product and clickSearch.For the D2000 disk enclosures and D2700 backup systems, enter the model number for the product and clickSearch.Select the appropriate operating system.SelectFirmware - SAS Storage Disk.Download and install the latest version of the firmware.Follow the installation steps detailed in the Release Notes to complete the firmware upgrade.Reboot the server to complete the installation.Drive ModelCorrected FirmwareDG0146BAMYQHPDDDG0146FARVUHPDDDG0300BAMYRHPDDDG0300FARVVHPDDEF0300FATFDHPD8EF0450FATFEHPD8EF0600FATFFHPD8EG0146FAWJCHPDDEG0300FAWJDHPDDEG0300FBDBRHPD7EG0450FBDBTHPD7EG0600FBDBUHPD7EH0072FARWCHPDAEH0146FARWDHPDATable 2: Corrected Firmware for Affected HP SAS Hard Drive ModelsRECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to HP SAS drives, use the following search string:+Advisory +ProLiant -"Software and Drivers" +SAS +drive
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.