Document VersionRelease DateDetails201/09/2012Added clarification to the firmware download and installation steps in the Resolution.112/20/2011Original Document Release.IMPORTANT: The hard drive firmware update in the Resolution section below is considered a critical fix and is required to prevent the issue detailed below. HP strongly recommends immediate application of this critical fix. Neglecting to perform the required action could leave the server in an unstable condition, which could potentially result in invalid data being written to the hard drive. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.After an unexpected loss of power an HP ProLiant, HP StorageWorks, or HP Integrity system configured with any of the HP SAS Solid State Drives (SSDs) listed in the Scope section (below) running firmware version HPD2, invalid data may (on rare occasions) be written from the SSD cache to the user data area on the SSD when powering the server on.Note:This is a rare issue that has not been reported in an HP customer environment. It was discovered in an HP lab environment during rigorous stress testing simulating multiple consecutive power outages.
HP ProLiant, HP StorageWorks, or HP Integrity system configured with any of the following HP Solid State Drives:Drive ModelDescriptionFirmwareVersionMO0200FBRWBHP 200GB 6Gb/sec SAS 2.5-inch Multi Level Cell Hot-plug Solid State DriveHPD2EO0200FBRVVHP 200GB 6Gb/sec SAS 2.5-inch Single Level Cell Hot-plug Solid State DriveHPD2MO0400FBRWCHP 400GB 6Gb/sec SAS 2.5-inch Multi Level Cell Hot-plug Solid State DriveHPD2EO0400FBRWAHP 400GB 6Gb/sec SAS 2.5-inch Single Level Cell Hot-plug Solid State DriveHPD2MO0800FBRWDHP 800GB 6Gb/sec SAS 2.5-inch Multi Level Cell Hot-plug Solid State DriveHPD2Figure 1: Affected HP SAS Solid State Drive ModelsNote:The Multi Level Cell SSDs listed above (MO0200FBRWB, MO0400FBRWC, and MO0800FBRWD) are not applicable to Integrity systems.To determine whether the above SSD models are configured in the server, use any of the following HP utilities:HP Array Configuration UtilityHP Array Diagnostic UtilityHP Insight DiagnosticsHP Systems Insight Manager (HP SIM)HP System Management Homepage (SMH)
To ensure that invalid data is not written from the SSD cache to the user data area on the SSD, upgrade to SAS SSD Firmware Version HPD5 (or later), which can be located for download using the following navigation:Firmware for SSD Models MO0200FBRWB, EO0200FBRVV, MO0400FBRWC, EO0400FBRWA, and MO0800FBRWDGo tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software.For ProLiant and Integrity servers, enter "MO0200FBRWB" or "EO0200FBRVV" or "MO0400FBRWC" or "EO0400FBRWA" or "MO0800FBRWD" for the product and clickSearch.For the D2200sb storage blade, enter "D2200sb" for the product and clickSearch.Select the appropriate operating system.(For Integrity systems, selectCross operating system (BIOS, Firmware, Diagnostics, etc.))SelectFirmware - SAS Storage Disk.Download and install the appropriate component for Firmware Version HPD5 (or later).Follow the installation steps detailed in the Release Notes to complete the firmware upgrade.Reboot the server to complete the installation.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to Solid State Drives, use the following search string:+Advisory +ProLiant -"Software and Drivers" +"Solid State Drive"
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.