HP D2200sb Storage Blade products are shipped with HP Smart Array Controller firmware version 3.70 or later. Applying Smart Update Firmware DVD Release 9.30 to a system with a D2200sb attached and online can force a downgrade to version 3.66, which is unsupported for the D2200sb, and can cause an incorrect immediate exceeded temperature thresholds shutdown. The risk of this issue causing an immediate shutdown is very low because it is due to a timing issue during periodic temperature analysis. This issue is resolved in HP Smart Array Controller firmware version 3.70.NOTE: During an exceeded temperature thresholds condition, the D2200sb will sound an alarm and display a temperature warning (front panel led indication) and messaging to the host for several minutes such as when the drawer is left extended out of the cooling path.
Products affected by this advisory are HP D2200sb PCIe Storage Blades.
Confirm the D2200sb was downgraded to version 3.66 or logged an immediate exceeded temperature thresholds shutdown (not due to a legitimate tray open event). Here is an example of an exceeded temperature thresholds condition reported by the GUI and in the syslog:Aug 19 09:37:07 OA: Blade 6 thermal state is CRITICAL.Aug 19 09:37:08 OA: Blade 6 is reporting failed health status.Aug 19 09:37:08 OA: Blade in bay 6 has been powered down.To resolve this issue, flash the D2200sb to version 5.06 or later.Go tohttp://www.hp.com/.SelectSupport & Drivers.SelectDrivers and Software.Enter"Smart Array P410"for the product name and selectSearch.SelectHP Smart Array P410/1G FBWC 2-ports Int PCIe x8 SAS Controller.SelectCross operating system (BIOS, Firmware, Diagnostics, etc.)Scroll to the tableFirmware - Storage Controllerto locate the"* RECOMMENDED * Online ROM Flash Component - Smart Array P212, P410, P410i, P411, and P812,"version 5.06 (or later), and selectDownload.Reboot the server to complete the installation.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.