The HP StorageWorks P2000 G3 MSA Array Systems in a Windows 2008 HyperV Cluster environment path failover might not complete when there are over 1024 Persistent Reservations (PR's) on the system. The following errors might be observed in the server cluster logs.2011/01/24-10:12:21.174 WARN [RES] Physical Disk <Cluster Disk 1>:PR reserve failed, status 170.
The product family affected by this advisory is HP StorageWorks P2000 MSA Disk Arrays.
The HP StorageWorks P2000 MSA Disk Arrays count total PR registrations on a system-wide basis until a limit of 1024 is reached. There might be one PR registration for every LUN up to a maximum of 128 per LUN until the 1024 system limit is reached. Reducing the number of PR registrations will eliminate the error and allow path failover to work correctly.