Loading...
Loading...
IMPORTANT: The hard drive firmware update in the Resolution section below is considered a critical fix and is required to prevent the issue detailed below. HP strongly recommends immediate application of this critical fix. Neglecting to perform the required action could leave the server in an unstable condition, which could potentially result in data corruption or loss. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.The HP SATA Solid State Drives (SSDs) listed in the Scope section below could potentially map data from an incorrect address as a result of a low-level hard drive background task. This background task periodically moves user data stored in physical flash memory locations to new memory locations to optimize memory usage. This issue only has the potential to occur if 30 KB of a 1 MB sequential write operation does not map to sequential physical memory locations due to the background task, which is highly unlikely to occur.IMPORTANT:This issue has not been reported in a production environment. It has only been observed during strenuous product testing on specialized test equipment.
Any HP ProLiant or StorageWorks server listed in the Platforms Affected section below configured with any of the following HP Solid State Drives:DescriptionModel NumberOption Kit NumberPart NumberSpares Kit NumberSATA Hot-plug 60GB 3G LFF (3.5-inch) Midline Solid State DriveMK0060EAVDR570761-B21570774-001570826-001SATA Hot-plug 120GB 3G LFF (3.5-inch) Midline Solid State DriveMK0120EAVDT570763-B21570774-002570827-001SATA Hot-plug 60GB 3G SATA SFF (2.5-inch) Midline Solid State DriveMK0060EAVDR572071-B21570774-001572252-001SATA Hot-plug 120GB 3G SATA SFF (2.5-inch) Midline Solid State DriveMK0120EAVDT572073-B21570774-002572253-001
To prevent this issue from occurring, upgrade to Solid State Drive firmware version HPG7 (or later), which can be located for download using the following navigation:Go tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software.Enter the drive model (for example, MK0060EAVDR).Select the appropriate operating system.SelectFirmware - SATA Storage Disk.Download and install* RECOMMENDED * Online ROM Flash Component for[operating system] - [MKxxxxxxxxx]and[MKxxxxxxxxx]DrivesVersion HPG7 (or later).RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to SATA Solid State Drives, use the following search string:+Advisory +ProLiant -"Software and Drivers" +SATA +"Solid State Drive"
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.