If an HP StorageWorks P4000 storage system or an HP LeftHand storage node is rebooted while connected to a Windows 2008 or 2008 R2 iSCSI host using Device Specific Module (DSM) then a Windows stop error (blue screen) might occur. The stop error indication is0x19 BAD POOL HEADER.
This issue affects the following platforms, if they are running an 8.x version of the HP StorageWorks P4000 SAN/iQ software and are connected to a Windows 2008 or 2008 R2 host:HP StorageWorks P4000 G2 SAN SolutionsHP LeftHand P4000 SAN SolutionsHP StorageWorks P4000 SAN/iQ softwareHP LeftHand NSM Storage
To prevent this issue from happening in the future, install the fix associated with Microsoft Knowledge Base article KB976443:http://support.microsoft.com/kb/976443