Loading...
Loading...
Document VersionRelease DateDetails409/28/2011Updated the Resolution section with separate navigation to the firmware for drive models DH0036BALWK and DH0146BALWN, which currently use SAS Hard Drive Firmware Version HPD3(B), and drive models DG0072BALVL, DG0146BAHZP, DG0146BALVN, and DG0300BAHZQ, which currently use SAS Hard Drive Version HPD4 (C).307/08/2011Added SAS hard drive models that are also affected by this issue.209/17/2010Updated with the availability of SAS Hard Drive Firmware Version HPD4 for SAS drive models DG0072BALVL, DG0146BAHZP, DG0146BALVN, and DG0300BAHZQ, and to update the location of the firmware on HP.COM.108/26/2010Original Document Release.IMPORTANT: The SAS hard drive firmware upgrade described in the Resolution section below is considered a critical fix and required to prevent or correct the issue detailed below. HP strongly recommends immediate upgrade of the SAS hard drive firmware. Neglecting to perform the required action could potentially result in logical drive detection failure during Power-On Self-Test (POST) and data loss. By disregarding this notification and not performing the recommended resolution, the customer accepts the risk of incurring future related errors.Upgrading the HP SAS hard drives listed in the Scope section (below) from firmware version HPD2 to HPD3 may lead to the drive being "Failed" by the Smart Array controller with the following indications:The SAS hard drive will not be seen by the Smart Array SAS controller after power-cycling the server.The SAS hard drive Fault LED will illuminate amber.Note:This issue does not affect any other HP SAS hard drive models.
Any ProLiant server or StorageWorks enclosure configured with any of the following HP SAS hard drives:DriveModelDriveDescriptionOption KitNumberSpares KitNumberAssemblyNumberDH0036BALWKHot-Plug 36GB 15K rpm, 2.5-inch SFF Dual-Port SAS418369-B21418397-001504064-001DG0072BALVLHot-Plug 72GB 10K rpm, 2.5-inch SFF Dual-Port SAS384842-B21389346-001504015-001DG0146BAHZPHot-Plug 146GB 10K rpm, 2.5-inch SFF Dual-Port SAS418367-B21418399-001492619-001DG0146BALVNHot-Plug 146GB 10K rpm, 2.5-inch SFF Dual-Port SAS418367-B21418399-001504015-002DH0146BALWNHot-Plug 146GB 3G 15k rpm, 2.5-inch SFF Dual-Port SAS504062-B21504334-001504064-003DG0300BAHZQHot-Plug 300GB 10K rpm, 2.5-inch SFF Dual-Port SAS492620-B21493083-001492619-002Table 1: Affected HP SAS Hard Drives
To prevent the SAS hard drive being "Failed" by the Smart Array controller, upgrade to the SAS hard drive firmware versions described below, which can be located using the following navigation:Firmware Upgrade for Drive Models DH0036BALWK and DH0146BALWNGo tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software(if this screen appears).Enter "DH0036BALWK" or "DH0146BALWN" for the product.Select the specific product on the following page if this page appears.Select the appropriate operating system.ClickFirmware - SAS Storage Disk.Download and install version HPD3 (B) or later of the SAS drive firmware.After the upgrade has completed, reboot the server to finish the installation.Firmware Upgrade for Drive Models DG0072BALVL, DG0146BAHZP, DG0146BALVN, and DG0300BAHZQGo tohttp://www.hp.com/SelectSupport & Drivers.SelectDrivers and Software(if this screen appears).Enter "DG0072BALVL" or "DG0146BAHZP" or "DG0146BALVN" or "DG0300BAHZQ" for the product.Select the specific product on the following page if this page appears.Select the appropriate operating system.ClickFirmware - SAS Storage Disk.Download and install version HPD4 (C) or later of the SAS drive firmware.After the upgrade has completed, reboot the server to finish the installation.If the SAS hard drive has been physically "Failed" by the Smart Array Controller, contact HP Customer Support for assistance and reference document numberc02489735.Contacting HP Customer SupportCustomers inside North America should call 1-800-334-5144.Customers outside of North America should go to the following URL to determine the appropriate Customer Support phone number:https://support.hpe.com/hpesc/public/homeRECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to HP SAS hard drives, use the following search string:+Advisory +ProLiant -"Software and Drivers" +"SAS hard drive"
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.