Running certain versions of HP Smart Update Firmware DVDs, SmartStart CDs and other Windows- based utilities may cause false drive failures on HP StorageWorks MSA1500cs with HP StorageWorks MSA20 SATA disk enclosures.This can potentially occur when running certain versions of HP Version Control Agent for Windows or HP Smart Update Manager that is available on certain versions of the HP Smart Update Firmware DVD, SmartStart CD, ProLiant Support Pack for Windows, and other Windows- based utilities on a server running Windows Server 2003 when attached to an HP StorageWorks 1500 cs Modular Smart Array (MSA1500cs) with an HP StorageWorks 20 Modular Smart Array (MSA20) SATA drive array. This can lead to the failing of a presented Unit to the host.This can only potentially occur whenallof the following conditions are met:Windows 2003 Server with SP2 installed.HP StorageWorks MSA1500cs with attached StorageWorks MSA20 SATA disk enclosures.Active/Active and Active/Passive configurations.Single or Dual controller StorageWorks MSA1500cs.A Unit is presented to the attached host from the MSA1500cs and is in good state (not rebuilding or offline).HP Version Control Agent for Windows or HP Smart Update Manager is run on the attached host.
Any HP ProLiant server running Windows Server 2003 SP2 when attached to an HP StorageWorks 1500 cs Modular Smart Array (MSA1500cs) with HP StorageWorks 20 Modular Smart Array (MSA20) SATA drive arrays and running the following versions of HP Version Control Agent for Windows or HP Smart Update Manager:HP Version Control Agent 2.2.0HP Version Control Agent 2.2.2.835HP Version Control Agent 6.0.0.840ORHP Smart Update Manager 3.5.x (available from the deliverables listed below):HP ProLiant Support Pack for Microsoft Windows Server 2003 8.26HP ProLiant Support Pack for Microsoft Windows Server x64 Editions 8.26HP ProLiant Support Pack for Microsoft Windows Server 2003 8.25 (A)HP ProLiant Support Pack for Microsoft Windows Server 2003 x64 Editions 8.25 (A)HP Workstation Support Pack for Microsoft Windows Vista x64 8.30HP Blade Workstation Support Pack for Microsoft Windows XP 8.30HP Smart Update Firmware DVD 8.50HP BladeSystem Online Firmware Bundle for Windows 1.60HP BladeSystem Matrix - Online Firmware Bundle for Windows 1.51HP StorageWorks MSA2000 Software Bundle for Microsoft Windows Server 2003 ia64 2.15HP StorageWorks MSA2000 Software Bundle for Microsoft Windows Server 2003 x64 2.15HP StorageWorks MSA2000 Software Bundle for Microsoft Windows Server 2003 x86 2.15OrHP Smart Update Manager 3.6.x (available from the deliverables listed below):HP BladeSystem Online Firmware Bundle for Windows 1.62HP BladeSystem Matrix - Online Firmware Bundle for Windows 1.61HP ProLiant Support Pack for Microsoft Windows Server 2003 8.30HP ProLiant Support Pack for Microsoft Windows Server 2003 x64 Editions 8.30HP Smart Update Firmware DVD 8.60
HP recommends that none of the software versions listed in the Scope section above be used on an HP ProLiant server running Windows 2003 SP2 when attached to an HP StorageWorks MSA1500cs with HP StorageWorks MSA20 SATA disk arrays.This issue has been corrected in the following software/deliverables:HP Version Control Agent for Windows Version 6.1.0.841 (or later)HP Smart Update Manager Version 3.7.0 (or later), which is available from the following deliverables:HP ProLiant Support Pack Version 8.40 (or later), which is available for download at the following URL:http://www.hp.com/go/foundationHP Smart Update Firmware DVD Version 8.70 (or later), which is available for download at the following URL:http://www.hp.com/go/foundationHP BladeSystem Online Firmware Bundle for Windows Version 1.70 (or later), which is available for download at the following URL:http://h18004.www1.hp.com/products/blades/components/c-class.htmlIf one of the software utilities listed in the Scope section above is run and causes SATA drives to falsely fail in an HP StorageWorks MSA20, perform the following steps to recover the drive:Power OFF the HP StorageWorks MSA1500csPower OFF all the HP StorageWorks MSA20 enclosuresPower ON the HP StorageWorks MSA20 enclosures. Allow 30 seconds for each column of bays to finish booting.Power ON the HP StorageWorks MSA1500cs.Once power up is completed, check status of the Units via the CLI. Any drives marked as Failed will need to be replaced. Units may need to be accepted to be presented back to the hosts. Use the CLI command "accept unit."RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisoryNAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.