Revision TableVersionDateDetails302 Sep 2010Updated Description adding events following software upgrade.Revised Resolution section stating issues can be ignored.224 Nov 2009Updated resolution section and clarified workaround procedure.127 Oct 2009Original document released.When upgrading to HP StorageWorks XCS 6.220, EMU code 4.18 is installed. Customers who have recently upgraded to XCS 6.220 can see EMU communication events logged in the controller event log for multiple enclosures. Typically, these events occur during the first fifteen minutes of the controller software upgrade.While this behavior has been observed with prior versions, XCS 6.220 does appear to exhibit the behavior with greater frequency. The event is logged is as follows:063ec513; The HSV210 controller has detected an enclosure on the Fibre Channel but is unable to communicate with the Drive Enclosure Environmental Monitoring Unit on the enclosure address bus or the Drive Enclosure Environmental Monitoring Unit is reporting an invalid enclosure number.These events are typically seen shortly after installation completes. They may also be seen with the same reporting pattern against multiple enclosures following the insertion or removal of a physical disk drive, fiber channel cable or I/O module, or when other fibre channel loop events occur that can result in a directed LIP-including a controller restart or resynchronization of one or both controllers. These events are very short in duration and have no impact on host I/O.
This EMU communication event occurs more frequently with XCS version 6.220 on HP StorageWorks 4000/6000/8000 and 4100/6100/8100 Enterprise Virtual Arrays.
While there is no impact on the operation of the HP EVA, the logging of the event messages results in WEBES callouts and could cause customer concern. HP has determined that when these events occur in the manner described in the “Description” section, they may be safely ignored, and no further action is required.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.