In rare cases HP Integrity rx3600 servers have been reported to experience repeated Machine Check Abort (MCA) during boot. The MCA will repeat until Maintenance Processor “RS” (Hard Reset) command is issued.
Rarely seen, only reported on HP Integrity rx3600 with “Core I/O board with VGA” AB463-67003 installed. All reported occurrences with processor type AB577A (18M Cache, 1.60 GHz, 533 MHz FSB) and Firmware Version: 03.01A (EFI) (13 Mar 2008) or later.No OS or system software dependencies.
The system may be temporarily recovered by use of the Maintenance Processor (MP) hard reset command (RS) to break the MCA cycle and allow a normal boot. However the system may experience a similar problem the next time it is rebooted.A more permanent solution can be obtained by installing System firmware package “4.11a” which includes BMC 5.25 and will prevent this specific problem from reoccurring.