Some users are experiencing tape drive detection issues with drives in the HP StorageWorks 1U SAS Rack Mount Kit.
Affected ProductsThis advisory affects the drives in the HP StorageWorks 1U SAS Rack Mount Kit.
To resolve this issue, try the following:Ensure that an HP StorageWorks SAS cable is being used:To connect to a SC44Ge or any other HBA with an external hybrid connector:– 2m cable 430064-001– 4m cable 430065-001To connect to an E500 or a different HBA with an external mini-SAS connector:– 2m cable 430066-001– 4m cable 430063-001Update the SAS HBA firmware to the latest revision.Try a cable that is 2m or less. If a less than 2m cable works and a longer cable does not, or a greater than 2m cable is required, then try the following:Open up the rack mount kit.Inspect the SAS repeater card and find the revision label. If the revision label is 0D or lower (as shown below), then contact HP Service to exchange the rack mount kit.NOTE: Do not try to bypass the repeater board on the back of the rack mount kit. That is not a supported configuration
Operating Systems Affected:Not Applicable