IMPORTANT: This firmware upgrade is required to prevent the issue detailed below. HP strongly recommends immediate application of this upgrade. Neglecting to perform the required action could result in the potential for subsequent errors to occur in the scenario described below. By disregarding this notification, the customer accepts the risk of incurring future related errors.IMPORTANT: This issue has ONLY been observed in a rigorous test environment and has NOT been reported in a customer production environment.HP has identified a rare potential for data write errors to occur on an HP Smart Array SAS/SATA or SCSI Controller RAID volume ONLY when ALL of the following events occur:A RAID 1 or RAID 1+0 logical drive has recently been configured or reconfigured using RAID Migration or Capacity Expansion, or has recently been rebuilt via Automatic Data Recovery.ANDThe logical drive is configured on an HP Smart Array SAS/SATA Controller (model E200, E200i, P400, P400i, E500, P600, or P800) or Smart Array SCSI Controller (model 5i, 532, 53xx, 6i, or 64xx) running the firmware versions listed in the Scope section (below).ANDThe controller has not yet completed a single pass of a Surface Analysis on the logical drive since the last configuration change, or since the last Automatic Data Recovery (drive rebuild) operation on this logical drive.ANDHost-initiated write activity is occurring to the logical drive concurrently with background Surface Analysis activity.
Any HP ProLiant, Integrity, Integrity Superdome, or HP 9000 server configured with one of the following HP Smart Array Controllers that is running the following firmware and configured for RAID 1 or RAID 1+0:Smart Array ControllerAffected Firmware VersionsSmart Array 5i/532/53122.66 (or earlier)Smart Array 5302/53043.54 (or earlier)Smart Array 6i/64xx2.80 (or earlier)Smart Array E200/E200i1.72 (or earlier)Smart Array P400/P400i4.12 (or earlier)Smart Array E5004.12 (or earlier)Smart Array P6001.98 (or earlier)Smart Array P8004.12 (or earlier)Table 1. Affected Smart Array Controller Firmware
This issue has ONLY been observed in a rigorous test environment and has NOT been reported in a customer production environment.To prevent the rare potential for data write errors in this scenario, upgrade the Smart Array Controller firmware to the latest version available. The current firmware versions are listed in Table 2 (below):Smart Array ControllerCorrected Firmware VersionsSmart Array 5i/532/53122.76 (or later)Smart Array 5302/53043.62 (or later)Smart Array 6i/64xx2.84 (or later)Smart Array E200/E200i1.74 (or later)Smart Array P400/P400i5.18 (or later)Smart Array E5005.18 (or later)Smart Array P6002.02 (or later)Smart Array P8005.18 (or later)Table 2. Corrected Smart Array Controller FirmwareLocating the Firmware Upgrades:Click on the following link:http://h20566.www2.hpe.com/portal/site/hpscSelect "Product Support > Download options > Drivers and Software."Enter a product name (e.g., DL380 Gen9) and click onSearch.Select the appropriate operating system.Click on the appropriate category.Locate, download, and install the appropriate System ROM/NIC firmware.RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HP.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HP.com, refer to theSearch Tips document.To search for additional advisories related to Smart Array Controllers, use the following search string:+Advisory -"Software and Drivers" +"Smart Array Controller"KEYWORDS: Smart Controller, SmartArray
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.