Revision TableVersionDateDetailsVersion 19/12/2008Original document releaseOn a computer that is running Microsoft Windows Vista or Windows Server 2008, the built-in backup application normally backs up data to a removable HP StorageWorks RDX cartridge disk drive. However, HP StorageWorks RDX cartridge disk drives are not recognized as available backup destinations by the built-in backup application in Microsoft Windows Vista or Windows Server 2008.
Affected products:AJ765A HP StorageWorks RDX 160 Internal Removable Disk Backup SystemAJ766A HP StorageWorks RDX 160 External Removable Disk Backup SystemAJ767A HP StorageWorks RDX 320 Internal Removable Disk Backup SystemAJ768A HP StorageWorks RDX 320 External Removable Disk Backup SystemDepending on your operating system, you could experience the following symptoms:If you use the Backup and Restore Center tool or the Back Status and Configuration tool on a Windows Vista-based computer, the removable RDX cartridge disk drive does not appear in theOn a hard disk, CD, or DVDlist.If you use Windows Server Backup tool on a Windows Server 2008-based computer, the removable RDX cartridge disk drive is mistakenly recognized as a DVD drive. You can continue the backup process by using the removable RDX cartridge disk drive; however, some backup and restore functionality is restricted for DVD media. For example, you receive the following error message when you try to restore individual files or folders from removable media:Recovery of individual files, folders, or application data from DVD or removable media is not supported.These symptoms occur even though the removable RDX cartridge disk drive appears in Windows Explorer as a disk drive.This issue occurs because the system incorrectly recognizes some removable RDX cartridge disk drives as unsupported backup destinations.
Hotfix informationA supported hotfix is available from Microsoft. However, this hotfix is intended to correct only the issue that is described in this article. Apply this hotfix only to systems that are experiencing this specific problem. This hotfix might receive additional testing, so if you are not severely affected by this issue, HP recommends that you wait for the next software update that contains this hotfix.If the hotfix is available for download, there is aHotfix download availablesection at the top of the Microsoft Knowledge Base article. If this section does not appear, contact Microsoft Customer Service and Support to obtain the hotfix.NOTE: If additional issues occur or if any troubleshooting is required, you might have to create a separate service request. The usual support costs will apply to additional support questions and issues that do not qualify for this specific hotfix. For a complete list of Microsoft Customer Service and Support telephone numbers, or to create a separate service request, go to the following Microsoft website:http://support.microsoft.com/contactus/?ws=support.NOTE: TheHotfix download availableform displays the languages for which the hotfix is available. If you do not see your language, a hotfix is not available for that language.PrerequisitesTo apply this hotfix on Windows Vista-based computer, you must have Windows Vista Service Pack 1 installed on the computer. For more information, click the following article number to view the article in the Microsoft Knowledge Base:935791How to obtain the latest Windows Vista service pack.No prerequisites are required for Windows Server 2008 computers.Restart requirementYou must restart the computer after you apply this hotfix.Hotfix replacement informationThis hotfix does not replace any other hotfixes.File informationThe English version of this hotfix has the file attributes (or later file attributes) that are listed in the following table. The dates and times for these files are listed in Coordinated Universal Time (UTC). When you view the file information, it is converted to local time. To find the difference between UTC and local time, select theTime Zonetab in theDate and Timeicon in Control Panel.Windows Vista and Windows Server 2008 file information notesThe files that apply to a specific product, milestone (RTM, SPn), and service branch (LDR, GDR) can be identified by examining the file version numbers, as shown in the following table:VersionProductMilestoneService branch6.0.6001.22xxxWindows Vista SP1 and Windows Server 2008 SP1SP1LDRThe.manifestfiles and the.mumfiles that are installed in each environment arelisted separatelyin theAdditional file information for Windows Server 2008 and for Windows Vistasection. These files and their associated.cat(security catalog) files are critical to maintaining the state of the updated component. The.catfiles are signed with a Microsoft digital signature. The attributes of these security files are not listed.For all supported x86-based versions of Windows Server 2008 and Windows VistaFile nameFile versionFile sizeDateTimePlatformDisk.sys6.0.6001.2222555,35218-Jul-200803:28x86For all supported x64-based versions of Windows Server 2008 and Windows VistaFile nameFile versionFile sizeDateTimePlatformDisk.sys6.0.6001.2222568,66418-Jul-200805:02x64For all supported Itanium-based versions of Windows Server 2008File nameFile versionFile sizeDateTimePlatformDisk.sys6.0.6001.22225131,64018-Jul-200804:55IA-64Proactive updatesReceive support alerts (such as Customer Advisories), driver updates, software, firmware, and customer-replaceable components in your e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice Driver, Patch, Security, and Support alerts at the following URL:http://www.hp.com/go/myadvisoryTo sign up for other Subscriber's Choice services, see:http://www.hp.com/go/e-updates
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.