In rare situations, the initial full copy (also known as normalization) or expansion of a virtual disk that is part of an HP Continuous Access EVA DR group does not complete the background allocation of the virtual disk at the target Enterprise Virtual Array. This document describes those circumstances and outlines what to monitor and how to resolve the issue.
This issue has been observed on HP StorageWorks 3000/5000/4000/4100/6000/6100/8000/8100 Enterprise Virtual Arrays running any of the following firmware versions:VCS 3.001, up to and including 3.110VCS 4.001, up to and including 4.100XCS 5.020, up to and including 6.0x0 and 6.1x0
With XCS 6.100 or later, some instances that could lead to this issue have been addressed. These changes are being investigated for inclusion in a future VCS release for the HP StorageWorks 3000/5000 Enterprise Virtual Array. There are no plans to update the VCS code stream. Investigation is ongoing to determine additional reasons that could cause the background allocation to stop. If any are found, they will be investigated for inclusion in a future release of firmware.If the DR group is not progressing in allocating the space for the virtual disk at the target EVA, use the steps outlined in the Workaround section.WorkaroundUse either of the following recovery options to restart the allocation for the virtual disk at the target EVA:Write data to the source virtual disk from the host or hosts with access to this Vdisk until the LUN is completely filled. This restarts and continues the allocation on the target virtual disk. Once completed, remove the file or files you created to fill the virtual disk.Use HP SSSU to change the preferred controller for the virtual disk, which moves the virtual disk at the target EVA to the non-owning controller. If progress stops, move the virtual disk back to the original controller. Repeat these steps until the allocated and requested sizes for the virtual disk are equal.The following is an example of how to use HP SSSU to determine and move the virtual disk from the owning controller to the non-owning controller. For more information about HP SSSU, see theHP StorageWorks Storage System Scripting Utility reference.NOTE: The output of the commands has been shortened at several locations and will only reflect the important fields required for the steps needed.Start HP SSSU and log on to the server that manages the destination EVA.At the SSSU prompt, select the destination EVA:NoSystemSelected> select system SpockVerify the allocated and requested capacity for the virtual disk using the LS VDISK command:If the fields for allocatedcapacity and requestedcapacity are equal, the background allocation has completed successfully. Proceed to step 10.If the fields are different, continue with the next step.Record the value of the controllername, diskgroupname, and preferredpath from the output. In the output in Step 3, they are Controller A, \Disk Groups\Default Disk Group and no_preference, respectively.If the EVA is not running XCS 6.200, verify that the disk group for the virtual disk is not currently in a migration state, using the LS DISK_GROUP “<name of disk group>” command:If the disk group is in a migration state and the array is not running XCS 6.200 wait for the migration to complete. Allocation will not continue while this disk is in the migration state.When the operationalstate field indicates attention, open HP Command View EVA and locate the disk group identified in Step 5. It should be identified with a warning triangle (Figure 1).Figure 1:Disk Group with warning triangleOpen the disk group to identify the disks with a warning triangle (Figure 2). Figure 2 indicates that a migration is ongoing. Wait for the migration to complete before continuing with the next step.Figure 2:Physical disk with warning triangleRestart the allocation process by moving ownership to the other controller. Use the HP SSSU SET VDISK command with the preferred_path option:Spock> SET VDISK “Vdisk001” PREFERRED_PATH=PATH_B_FAILOVERNOTE: The controllername field (from Step 3) indicates which controller currently owns the virtual disk. In this example, it is Controller A.If the allocated size for the virtual disk has not progressed for 15 minutes or more, and it is not equal to the requested size, verify that there are no connectivity issues between the EVAs. If there are no connectivity issues, it is likely that the background allocation has halted again. Return to Step 3.When the allocated and requested sizes are equal, change the preferred path back to the original setting recorded in Step 4:Spock> SET VDISK “Vdisk001” PREFERRED_PATH=<previous_settings>NOTE: If the original setting was no_preference, use the following command: Spock> SET VDISK “Vdisk001” NOPREFERRED_PATHCustomer Problem ResolutionIn the event of a specific failure, diagnostic, symptom, or other customer issue, use theCPR (Customer Problem Resolution)process to obtain assistance. Typically, this means contacting the responsible Global Competency Center (GCC) team. Onsite support personnel can access the GCC through the country/region remote support center. You must provide theremotesupport center with all of the pertinent system or software information (serial numbers, model numbers, logs, and so on).Proactive UpdatesReceive support alerts (such as Engineering Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HP Reader’s Choice. Sign up for Reader’s Choice at the following URL:https://readerschoice.itcs.hpecorp.net/rcuser/Home.do
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.