In an HP Continuous Access EVA configuration with an HP StorageWorks Enterprise Virtual Array 4000, 4100, 6000, 6100, 8000 or 8100 running XCS 6.000 or later, a remote EVA sometimes displays as Unknown when viewing the Data Replication Folder Properties page in HP Command View EVA or in the output of the LS FOLDER command for the Data Replication folder in SSSU.With the release of XCS 6.000, HP Continuous Access EVA maintains a list of possible target EVAs that are available within its data structures. When a remote EVA is discovered, the information about that EVA is stored persistently. Therefore, the remote EVA remains available in HP Command View EVA even if the EVA is no longer visible. When the HP Command View EVA service is restarted, the name of the remote EVA changes to Unknown if the array is not discovered again. The following screenshot shows an example of an Unknown array on the Data Replication Folder Properties page:The following output shows an example of an Unknown array when executing the LS FOLDER command on the Data Replication folder:McCoy> ls folder "\Data Replication\" \Data Replication\ information: object objectid .............................: 0808080808080808080808080808080808080808 objectname ...........................: \Data Replication\ objecttype ...........................: drmgroupfolder objectwwn ............................: objecthexuid .........................: 0808-0808-0808-0808-0808-0808-0808-0808 uid ..................................: 2056.8.8.134744072.134744072.134744072.134744072 objectparentuid ......................: 8.7.16.1610942644.1059474.53248.26869760 objectparenthexuid ...................: 6005-08b4-0010-2a92-0000-d000-019a-0000 objectparentid .......................: 08000710B4080560922A100000D0000000009A01 totaldrmgroups .......................: 8 totalmembervirtualdisks ..............: 8 nbscellconnections ...................: 5 remote_sc_name_0 .....................: Unknown MANAGED_0 ............................: No DR_LIC_0 .............................: N/A remote_wwn_0 .........................: 5000-1FE1-500B-B220 paths_to_remote_scell_0 ..............: 0 DR_ACTIVE_0 ..........................: No remote_sc_name_1 .....................: Vulcan MANAGED_1 ............................: No DR_LIC_1 .............................: N/A remote_wwn_1 .........................: 5000-1FE1-0015-2880 paths_to_remote_scell_1 ..............: 2 DR_ACTIVE_1 ..........................: No remote_sc_name_2 .....................: Sybok MANAGED_2 ............................: Yes DR_LIC_2 .............................: Yes remote_wwn_2 .........................: 5000-1FE1-0027-0F00 paths_to_remote_scell_2 ..............: 16 DR_ACTIVE_2 ..........................: Yes remote_sc_name_3 .....................: Unknown MANAGED_3 ............................: No DR_LIC_3 .............................: N/A remote_wwn_3 .........................: 5000-1FE1-5001-E100 paths_to_remote_scell_3 ..............: 0 DR_ACTIVE_3 ..........................: No remote_sc_name_4 .....................: Seven MANAGED_4 ............................: No DR_LIC_4 .............................: N/A remote_wwn_4 .........................: 5000-1FE1-5001-1C30 paths_to_remote_scell_4 ..............: 4 DR_ACTIVE_4 ..........................: NoRestarting the EVA and/or HP Command View EVA does not clear the Unknown EVA from the list.
HP StorageWorks Enterprise Virtual Array 4000, 4100, 6000, 6100, 8000 and 8100 installations using Continuous Access EVA and running XCS v6.000 or later
The Unknown EVA information can be safely ignored. A resolution for removing this “orphaned” data is planned for a future version of HP Command View EVA.Proactive UpdatesReceive support alerts (such as Customer Advisories), driver updates, software, firmware, and customer replaceable components, in your e-mail through HP Subscriber's Choice. Sign up forSubscriber's Choice Driver, Patch, Security, and Support alertsat the following URL:http://www.hp.com/go/myadvisoryTo sign up for other Subscriber's Choice services, see:http://www.hp.com/go/e-updates
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.