DESCRIPTIONTru64 Unix servers that use Raid Array 3000 (RA3000) based storage sets may experience a change in device special file designations after a RA3000 controller (HSZ22) restart under specific circumstances. This change is seen only after the first controller restart or power cycle upon the creation of a LUN from a partitioned storage set.A partitioned storage set is a storage set from which 2 or more logical units are presented. This issue is seen as Hardware ID and Device Name changes on presented devices.
SCOPEHardware products affected are all RA3000 Storage Systems presenting units from partitioned storage sets. This problem has been observed on RA3000 with D11W and D11X firmware with all Tru64 Unix supported versions. Other operating systems are not affected.Indications of the issue include devices no longer available on reboot of the Tru64 Unix Host. When this occurs, a new device representation is created and the previous device is no longer available to the operating system for use.Cause of this issue is a change to the World Wide ID (WWID) of the presented unit by the HSZ22 controller firmware upon restart. The WWID of the second and subsequent units presented by the controller are subject to this change. This change will be triggered by controller restart or power failure and subsequent restart of controller.
RESOLUTIONA permanent resolution is under investigation. Once available, an update will be published immediately. At present, HP has several recommendations for this issue:· Restart the controller once after the creation of any partitioned storage sets (in the case of new installations) and also prior to any OS installation. The changes are only seen on the first restart or power recycle of the controller. After that the WWIDs of the presented units remain constant.· If you are dynamically creating disk sets and a controller restart is not possible, it is recommended that you avoid creating units from partitioned storage sets.Aside from these guidelines, there are specific steps that should be taken in Tru64 environments using the specified Storage Devices:If you have an existing Tru64 installation and need to create units from partitioned storage sets, it is necessary to:1) Shut down your Tru64 server2) Use SWCC to configure and partition your RAID set3) Use SWCC to restart your controllers4) Reboot your Tru64 server to find and use the newly presented units.Downloadable SolutionsDownloadable FileLocationNone
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.