Due to architectural incompatibilities with Secure Path, Service Pack 3 for Microsoft Windows 2000 is not currently supported on systems running Secure Path V3.1A for Windows for RA4000/RA4100 or Secure Path V3.1B for Windows Workgroup Edition with an MSA1000 using firmware version 1.16. As a result, if Service Pack 3 is installed, these systems will fill the System Event Log with Event ID 772 errors that falsely indicate a redundant fibre path failover. There may be subsequent performance degradation due to the frequency of these messages being posted to the event log. These Event ID 772's will occur primarily during system start-up and intermittently during system operation.Note: MSA1000 and RA4X00 systems not running Secure Path are not affected.
Any systems running Secure Path V3.1A for Windows for RA4x00 or Secure Path V3.1B for Windows Workgroup Edition with Microsoft Windows 2000 Service Pack 3 installed are affected.Note: This issue does not affect HP EVA, HSG, MA or other HP storage solutions. This only occurs if Secure Path is installed on an RA4000, RA4100 or MSA1000 Storage System.
MSA1000: There are 2 methods to permanently resolve this issue.The first method only requires an upgrade to the MSA1000 controller ROM to version 1.18. This is available for download from the 1.18 firmware link on:http://h18000.www1.hp.com/products/storageworks/msa1000/index.htmlThe Second method is to upgrade the controller to firmware 2.38 or later. As this firmware upgrade also enables multi-node cluster support and other enhancements it does require that the following components are also upgraded:FCA2101 HBA driver 5.4.82A9 or laterEMU firmware 1.86 or laterACU 6.0 or laterSecure Path 4.0 Workgroup EditionNote: The 2.38 firmware and all of the other required upgrade components are available on the HP website at:http://h18000.www1.hp.com/products/storageworks/msa1000/index.html. These are available at no charge to existing customers.RA4000/RA4100:The HBA driver for the RA4X00's has been modified to permanently resolve this architectural issue. The driver has successfully completed all HP qualification and regression tests. This driver should be released within the first half of January at which time and this document will be updated. Future versions of this driver will also incorporate these changes. This update will be available at:http://h18000.www1.hp.com/products/storageworks/softwaredrivers/ra4100sanss/index.htmlNote: Microsoft is developing a Hotfix that resolves this issue. Upon successful completion of qualification and regression testing it will be made available.Downloadable SolutionsDownloadable FileLocationnone
Operating Systems Affected:Microsoft Windows 2000
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.