Document VersionRelease DateDetails212/12/2007Update Resolution with latest firmware versions.110/05/2007Original Document Release.IMPORTANT:The firmware upgrades listed in the Scope section below are required to prevent the issues detailed below. HP recommends performing the upgrades at the customer's earliest convenience. Failure to perform the required action could result in the potential for subsequent errors to occur on the SAS hard drives listed in the Scope section below.The HP SAS hard drives (listed in the Scope section below) may randomly become inaccessible during normal operation. When this occurs, the drives will remain inaccessible even after resetting the drives or controller or after rebooting the server.Note:Proactive replacement of these drives due to this issue is neither warranted nor authorized.
Any of the HP SAS hard drives listed in Table 1 (below) and running one of the firmware versions listed under "Firmware."DescriptionPart NumberModelFirmware146GB 10K SAS Single Port 2.5"431954-003DG146ABAB4HPD2HPD4HPD5HPD772GB 10K SAS Single Port 2.5"431954-002DG072ABAB3HPD2HPD4HPD5HPD7300GB 15K SAS Single Port 3.5"431943-004DF300ABAAAHPD3HPD5146GB 15K SAS Single Port 3.5"431943-003DF146ABAA9HPD3HPD572GB 15K SAS Single Port 3.5"431943-002DF072ABAA8HPD3HPD536GB 15K SAS Single Port 3.5"431943-001DF036ABAA7HPD3HPD572GB 15K SAS Single Port 2.5"431930-002DH072ABAA6HPD2HPD436GB 15K SAS Single Port 2.5"431930-001DH036ABAA5HPD2HPD4Table 1. HP SAS Hard Drives That May Become Inaccessible
Proactive replacement of these drives due to this issue is neither warranted nor authorized.To prevent these drives from becoming inaccessible, or to restore them to normal operation when this occurs, upgrade to the corrected firmware versions listed in Table 2 (below) by clicking on the Smart Component number below or by searching on the Smart Component number listed in the table. Begin the search at the Software and Driver Downloads web page at the following URL and enter the Smart Component number in the Search box at the upper right side of the screen:Software and Driver Downloadshttps://support.hpe.com/hpesc/public/homeFor example, Figure 1 (below) indicates the search box location where the Smart Component number should be entered.Figure 1. Searching for Smart Component CP008126Description andPart NumberModelCorrectedFirmwareSmart Component146GB 10K SASSingle Port 2.5"P/N 431954-003DG146ABAB4HPDACP008433(Windows)CP008449(Linux)72GB 10K SASSingle Port 2.5"P/N 431954-002DG072ABAB3HPDACP008433(Windows)CP008449(Linux)300GB 15K SASSingle Port 3.5"P/N 431943-004DF300ABAAAHPD8CP008443(Windows)CP008447(Linux)146GB 15K SASSingle Port 3.5"P/N 431943-003DF146ABAA9HPD8CP008443(Windows)CP008447(Linux)72GB 15K SASSingle Port 3.5"P/N 431943-002DF072ABAA8HPD8CP008443(Windows)CP008447(Linux)36GB 15K SASSingle Port 3.5"P/N 431943-001DF036ABAA7HPD8CP008443(Windows)CP008447(Linux)72GB 15K SASSingle Port 2.5"P/N 431930-002DH072ABAA6HPD7CP008442(Windows)CP008448(Linux)36GB 15K SASSingle Port 2.5"P/N 431930-001DH036ABAA5HPD7CP008442(Windows)CP008448(Linux)Table 2. HP SAS Drives and Available Firmware UpgradesTo return these drives to normal operation (if this occurs before the firmware can be upgraded) perform either of the following:For hot-pluggable drives only, hot-remove and hot-add the affected drives.ORGracefully shut down and power off the server (and any attached enclosure). Power the enclosure back on and then power on the server.Note:The firmware upgrade also corrects the issue addressed in Customer Advisory c01296286:https://support.hpe.com/hpesc/public/docDisplay?docId=c01296286RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisorySEARCH TIP: For hints on locating similar documents on HP.com, refer to the Search Tips document:https://support.hpe.com/hpesc/public/docDisplay?docId=c00638154.To search for additional advisories related to SAS hard drives, use the following search string:+Advisory +SAS +driveKEYWORDS: not found, missing, offline, unavailable
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.