Since the release of WEBES that supports the gathering and transfer of ELCs (EVA Log Collections) using ISEE, there have been situations that prevented these files from being transferred to HP. Research has shown the primary reasons for these failures are:The Managed Entities information in WEBES is incomplete. This includes the city, state, postal code, and contact information for each support entity.The sizes of the collected files are too large. This can be minimized in older versions of WEBES by keeping the WindowsApplication.evtfile under 5 megabytes. This affects version 4.4.4. Version 4.5 or later “filters” theApplication.evtfile to minimize the size. However, the other collected files can still cause the zip file to be too large. Currently, there is no way to effectively manage these files to reduce the size.
WEBES 4.4.4, WEBES 4.5, WEBES 4.5RU1, WEBES 4.5.1, WEBES 5.0
To resolve this issue, verify that the information for the Managed Entities is complete. This is for all entities that WEBES manages. There are several fields that might indicate they are not required, but in fact, they are required; for example, the ‘State field.Complete the following steps:Log into the WEBES GUI:http://localhost:7902/SEA Settings(1).SelectDirector Settings(2).SelectManaged Entities(3).SelectSites(4).Create a new site or edit existing sites:Verify that you have entered information for all of the fields marked with an asterisk.ClickApply Changes. Go back to Managed Entities (Step 1 of this document)Verify that every Managed Entity refers to an existing site. In theChoose a Sitefield, select a site from the dropdown menuFrom a DOS window issue the following commands:DOS>net stop desta_serviceDOS>net stop wccproxyDOS>desta dri set ISEE.trylocal falseDOS>net start desta_serviceCustomers running versions below WEBES 4.5.1 should upgrade to at least 4.5.1 or the current release. For the current release visit:https://support.hpe.com/hpesc/public/homeRECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), driver updates, software, firmware, and customer replaceable components, in your e-mail through HP Subscriber's Choice. Sign up forSubscriber's Choice Driver, Patch, Security, and Support alerts at the following URL:http://www.hp.com/go/myadvisoryTo sign up for other Subscriber's Choice services, see:http://www.hp.com/go/e-updates
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.