Revision #Revision DateRevision Details229 June 2007Updated the document to announce v5 build 268 replacing build 25318 June 2007Original Document ReleaseHP is pleased to announce the release ofWeb-Based Enterprise Services (WEBES) 5.0.HP recommends that all customers using WEBES to manage the HP StorageWorks Enterprise Virtual Array (EVA) upgrade to 5.0.HP strives to continually improve and enhance WEBES rules and diagnostics. As a result, it is important for customers to be using the most current version of WEBES. When connected to Instant Support Enterprise Edition (ISEE), the tools can be configured to transmit status information directly to HP Service Centers for proactive resolution of issues. Customers can also configure WEBES to a local notification source for monitoring the EVA.To install version 5.0, go to:http://www.hp.com/services/webes/The original WEBES 5.0 (build 253) Windows Pentium kit posted on June 18th 2007 has been replaced with build 268. WEBES 5.0 (build 253) was released to support HP Command View EVA v7.0 customers, as this application requires WEBES 5.0 to properly support the EVA.The new kit is identified by its build number - WEBES 5.0 Build 268, and is the recommended kit for installation. If you have obtained the older kit (build 253) and not installed it as yet, download build 268. If you have installed the older kit, it can be replaced at your convenience. We always recommend the most recent release be installed.NOTE: The degradation will vary based on the size of the event log being analyzed. We have observed in our labs Manual Analyses run times that can take 4 to 6 times longer than WEBES 4.5.1. We are working to determine the root cause and resolve this issue in a future release.When replacing build 268 with build 253 you must uninstall HP WEBES 5.0 (Remove) using the add or remove program feature in Windows. If you are running with ISEE, you should also uninstall WCCProxy.NOTE: During the uninstall of HP WEBES 5.0 be sure to click Yes on the question to save data. Refer below to the screen shot of the pop up message you will see.
WEBES 5.0 has been released for the following platforms only:Windows Pentium-based systemsHP ProLiant servers with HP StorageWorks Command View EVAHP OpenView Storage Management Appliances, managing HP StorageWorksEVA systems listed in the Supported Products section of Chapter 1 in the SystemEvent Analyzer (SEA) User Guide.WEBES 5.0 supports the following EVA products:HP Storage Works EVA4000/6000/8000 products with XCS 6.1xx or earlierHP Storage Works EVA4100/6100/8100 products with XCS 6.110HP Storage Works EVA3000/5000 with VCS 4.007 and/or 3.1xx or earlierHP StorageWorks Command View EVA management software 7.x or earlierNOTE: HP StorageWorks Command View EVA 7.x has changed the format of events written to the NT Application Event Log and only WEBES 5.0 can properly read these events. Therefore,WEBES 5.0 is required when installing or upgrading to HP StorageWorks Command View EVA 7.x.
New features and fixes in WEBES 5.0 for Windows Pentium include:Provide the controller serial number in callout reports and HP Command View EVA 7.0.Identify new controller type (CR2) in controller reports for arrays running XCS 6.110 or later.Implement fixes to produce a single report for an operator action (rebooting, power up, etc.) instead of multiple reports.Provide a decoded ASCII text for severity. Instead of a number, the report indicates severity by description (e.g., critical, major, etc.).Use the SNMP Type 3 trap design for all rules.Add Sense Key for ASC/ASCQ codes.Report old events. This is the algorithm that will detect when HP Command View EVA duplicates old log entries into the NT application log.Important:If the Windows Application Event Log is not cleared, WEBES will scavenge and reproduce callouts for past service events after version 5.0 has been installed. If service has recently been required, HP strongly recommends that you clear this log before installing version 5.0.RECEIVE PROACTIVE UPDATES:Receive support alerts (such as Customer Advisories), driver updates, software, firmware, and customer replaceable components, in your e-mail through HP Subscriber's Choice. Sign up forSubscriber's Choice Driver, Patch, Security, and Supportalerts at the following URL:http://www.hp.com/go/myadvisoryTo sign up for other Subscriber's Choice services, see:http://www.hp.com/go/e-updates
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.