Loading...
Loading...
Revision #Revision DateRevision Details22-Apr-2007Updated the document to indicate that the issue has been resolved and customers can now upgrade to VCS v4.007.117-Jan-2007Original Document ReleaseHP StorageWorks 3000/5000 Enterprise Virtual Array (EVA) Storage Systems may be upgraded to Virtual Controller Software (VCS) v4.007 at this time. The issue where the storage solution was reporting Missing Data events has been resolved. The root cause of the issue has been identified. A fix has been developed, tested and qualified and is now available to customers via the VCS v4.007 system software release. Customers who experienced the Missing Data events issue should upgrade immediately to VCS v4.007. Customers who require active/active controller failover configurations can now upgrade to VCS v4.007.Refer to the document c00864124 HP StorageWorks 3000/5000 EVA System Software Release VCS v4.007 for additional information at the following URL:https://support.hpe.com/hpesc/public/docDisplay?docId=c00864124HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA) Storage Solutions should not be upgraded to Virtual Controller Software (VCS) v4.004 at this time.HP StorageWorks Division is requesting that all upgrades from VCS v3.028 to v4.004 be delayed until a resolution to an issue where the array is reporting Missing Data events can be provided.After completion of an upgrade from VCS v3.028 to VCS v4.004, the storage solution may begin reporting Missing Data events, event code 061d4709,A Fibre Channel exchange to a physical disk drive has completed but is missing data.The frequency of occurrence of the missing data events varies by system.Missing Data events are generated by an error handler put in place to detect lost frames of a read from the backend disks. A read that results in a Missing Data event is retried and does not disrupt the operation of the array. Occasional Missing Data events are tolerated as part of normal storage system operation. Large numbers of Missing Data events may affect the array performance and data accessibility.Missing Data events do not affect data integrity.Customers who have already installed or upgraded their EVA 3000/5000 to VCS v4.004 and are not seeing, or are seeing occasional Missing Data events, can continue to run without concern over this issue.
EVA 3000/5000 storage systems running VCS v3.028 that are planning on upgrading to VCS v4.004.NOTE: Only customers who require an active/active controller failover configuration should upgrade their EVA 3000/5000 to VCS v4.004 to enable support for that configuration. VCS v3.028 is intended for use in configurations that are active/passive controller failover. VCS v4.004 is intended for use in configurations that are active/active controller failover. VCS v4.004 is not a sequential upgrade from VCS v3.028. The upgrade path for active/passive environments from v3.028 is v3.100.
HP StorageWorks Division is requesting that all upgrades for EVA 3000/5000 to VCS v4.004 be delayed at this time. Customers should not upgrade to VCS v4.004 until StorageWorks engineering is able to provide a resolution to this issue.The StorageWorks Division has identified the root cause for this issue. A fix has been developed, tested and qualified and is now available to customers via the VCS v4.007 system software release. Customers who experienced the Missing Data events issue should upgrade immediately to VCS v4.007. Customers who require active/active controller failover configurations can now upgrade to VCS v4.007.RECEIVE PROACTIVE UPDATES:Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisory
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.