Loading...
Loading...
HP StorageWorks Enterprise Virtual Array (EVA) 3000/5000 Storage Systems using VCS v3.x should not upgrade to VCS v4.007 unless they require active/active controller failover functionality or one of the enhancements listed below.ISSUE DETAILSEVA 3000/5000 Storage Systems provided only active/passive controller failover functionality up to and including controller firmware version v3.110. Active/passive controller failover functionality provides a path to the data through a single. Active/passive controller failover functionality can be combined with multi-path host based software provides multiple paths to the data, but through a single storage system controller.With the introduction of the VCS v4.x controller firmware, the EVA3000/5000 Storage Systems now provide active/active controller failover functionality. Active/active controller failover functionality enables data access through both of the storage system controllers. Combined with the native operating system based multi-path software multiple paths to the data are available through both storage system controllers. VCS v4.x does not support active/passive controller failover configurations.VCS v4.007 is the current system software version for this active/active controller failover configurations.Enhancements to VCS v4.x include:Support for active/active controller failover, allowing the use of popular industry multipathing solutions and native host bus adapters.Support Container Services (3-phase snapclones) reducing host impact due to the amount of time required to create a snapclone.Support for 1024 virtual disks.Improved Continuous Access performance over distance.Added VMware host mode. It will no longer be necessary to use the custom host mode for VMware hosts.The latest version of VCS v3.x, VCS v3.110, is intended for use active/passive controller failover configurations. The upgrade path for customers running VCS v3.02x, v3.100 is to upgrade to VS v3.110.The latest version of VCS v4.x, VCS v4.007, is intended for use in active/active controller failover configurations. The upgrade path for customers running VCS v4.00x is to upgrade to VS v4.007Upgrading to VCS v4.007 should not be considered unless the customer requires support for an active/active controller failover configuration or one of the other enhancements provided in VCS v4.x. Upgrading to an active/active controller failover configuration requires changes to the configuration (including the connections) of the EVA 3000/5000 as well as changes to the operating system and other components in the SAN.NOTE: It is necessary to verify that all virtual disks are set to mirrored cache mode prior to upgrading from VCS v3.x. Mirrored cache mode is required with VCS v4.007 and this mode cannot be changed after the upgrade is performed.NOTE: The Online Disk Drive code load functionality available when running VCS v3.1x0 and Command View EVA v6.0.2 is NOT currently available using any version of VCS v4.00x.
EVA3000/5000 storage systems using VCS v3.x
Only customers who are upgrading to or require an active/active controller failover configuration should upgrade the EVA3000/5000 system software from VCS v3.x to VCS v4.007.RECEIVE PROACTIVE UPDATES:Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/e-updates
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.