Loading...
Loading...
HP StorageWorks Division is pleased to announce theavailability of Virtual Controller Software (VCS) v3.100. This version is a general availability maintenance release version for HP StorageWorks 3000/5000 Enterprise Virtual Array (EVA) storage systems. It is now available for Customer Self Upgrade (CSU). For full instructions about updating product software (including disk drive firmware), seeHP StorageWorks 3000/5000 Enterprise Virtual Array updating product software guide VCS 3.100,document 5697-6376.This document can be found at the following URL:https://support.hpe.com/hpesc/public/homeIn the storage section, clickDisk Storage SystemsIn theEVA Disk Arrayssection, click either theHP StorageWorks 3000 Enterprise Virtual ArrayorHP StorageWorks 5000 Enterprise Virtual Arraylink.VCS v3.100 can be found at the following URL:https://support.hpe.com/hpesc/public/homeIn thestoragesection, clickDisk Storage SystemsIn theEVA Disk Arrayssection, click either theHP StorageWorks 3000 Enterprise Virtual Arrayor theHP StorageWorks 5000 Enterprise Virtual Arraylink.Select your EVA productClickCross operating system(BIOS, Firmware, Diagnostics, etc.).Two options to upgrade the EVANOTE: Option 1 is the preferred option.Option 1:Customer Self Upgrade (CSU)If an HP customer is currently in a supported configuration running VCS v3.028 and HP Command View EVA v5.x or v6.x, then the only required task is to update the EVA 3000/5000 with VCS v3.100.There are no changes in the dependency of Host Bus Adapter (HBA) firmware and/or drivers, or in the dependency of Fibre Channel switch firmware between VCS v3.028 and v3.100. This is true for any supported operating systems attached to VCS v3.028. Therefore, this upgrade can be accomplished by an HP customer.NOTE: It is recommended that you download and check the most recent VCS v3.100 Release Notes for changes before updating VCS. This document will contain the most recent information which can change dynamically while this advisory can be out of date.Option 2:Call HP to have an HP field representative perform the upgradeIf the EVA is still under warranty and/or the HP customer has purchased a service contract, they may have HP perform the upgrade.Online CapabilityHP supports performing VCS firmware upgrades as well as disk drive firmware upgrades for the EVA storage arrays while applications and servers remain online. Successful online firmware updates require proper implementation of the EVA array, as well as appropriate I/O timeout parameters and other settings for application, clustering, HBA, and multipathing.See HP StorageWorks Enterprise Virtual Array online firmware upgrade best practices (5697-6388).This document can be found at the following URL:https://support.hpe.com/hpesc/public/home.In thestoragesection, clickDisk Storage SystemsIn theEVA Disk Arrayssection, click either theHP StorageWorks 3000 Enterprise Virtual ArrayorHP StorageWorks 5000 Enterprise Virtual Arraylink.Online Disk Firmware CapabilityAlthough it is not required that the disk drive firmware be upgraded at the same time as the system software, it is strongly recommended that you perform the two tasks together. The disk drive firmware supplied with the system software upgrade complements the operation of the controller firmware; for best results, the two should be used together. The firmware on all disk drives can be upgraded online. It requires, at a minimum, VCS v3.100, HP Command View EVA v6.0.2, and the disk drive Bundled Image (BI) file to be installed. The BI file contains disk firmware files.The BI file can be found at the following URL:https://support.hpe.com/hpesc/public/homeHP Command View EVA v6.0.2 can be found at the following URL:https://support.hpe.com/hpesc/public/homeIn the storage section, clickStorage Software.In the Storage Device Management Software section, clickHP StorageWorks Command View EVA.Select the appropriate kit and then select the operating system.NOTE: At the time of this advisory, HP Command View EVA v6.0.2 has not been released. This will be announced in a revision of theHP STORAGEWORKS ENTERPRISE VIRTUAL ARRAY XCS V6.000 RELEASEadvisory.The following issues are fixed in v3.100General issues:An issue where the failure of a single drive failure leads to a VRAID1 inoperative state has been addressed.The fault detection logic on the backend that prevents unnecessary disk and port failures is enhanced.An issue caused by a power cycle on the backend loop switch leading to the failure of device (backend) port connected to the loop switch resulting in a single port on fibre (SPOF) condition of the affected device ports has been addressed.During regeneration of a failed disk drive, error monitoring thresholds are suspended to remove the possibility of soft errors leading to a dual disk failure within a single redundant storage set (RSS).An issue of incomplete LUN deletion caused by a host write to unmapped space of a virtual disk while background allocation is in progress has been addressed.A cache memory leak, which can occur with a high number of write retries on the HP Continuous Access tunnel during a write load, and results in missing data in the tunnel has been addressed.Extended event information for loop recovery events (0x63b0008 events) is now provided to assist support personnel with analysis.Detailed information of array re-initialization events have been added into the controller termination logs.Progress indicator which indicates the progress of disk drive ungroup operations is now provided in HP Command View EVA.Within an HP Continuous Access EVA environment fault isolation between source and the destination EVAs has been enhanced.An issue that could lead to data inconsistency between the source and the target arrays in an HP Continuous Access EVA environment has been addressed.An issue that could lead to stalling of reconstruction or merging on VRAID5 disk groups is fixed.Controller Termination Issues.An issue where heavy use of a management command to gather virtual disk information could lead to a controller restart has been addressed.An issue where creation of a snapshot unit that led to an over commit condition on the array could cause a controller restart condition has been addressed.An issue where an errant response from a disk drive led to a controller termination has been addressed.An issue that led to a controller restart when code load operations were performed during HP Continuous Access EVA activity has been addressed. See theHP StorageWorks EVA3000/5000 Enterprise Virtual Array release notes(VCS 3.100).An issue that caused a controller termination due to a site failover, occurring before a disk group was brought online, has been addressed.An issue that caused a controller termination when loop recovery operations and device discovery operations occur at the same time has been addressed.An issue resulting in controller restart during storing or retrieval of LUN numbers has been addressed.An issue of non-sequential execution of commands resulting in a controller restart has been addressed.An issue that could, under certain instances, lead to a controller termination due to accessing unallocated memory address in the policy memory has been addressed.In HP Continuous Access EVA configurations consisting of EVA3000/5000 source units and EVA4000/6000/8000 destination unit DR groups, an issue that can lead to controller termination due to removing a DR group member with which snapshots are associated has been addressed.An issue where controller termination could result from access to a LUN that is being removed from a DR Group has been addressed.EVA Remote Support ToolsHP recommends that Instant Support Enterprise Edition (ISEE) be installed with the upgrade to VCS v3.028. This is a no-charge feature for any Enterprise Virtual Array while under warranty or service support. This tool enables self-monitoring and diagnosis. ISEE can significantly reduce the time required to isolate and correct issues. As required by customers’ site constraints, the tool can be configured to transmit status information directly to an HP service center for proactive issue resolution or to a customer contact for monitoring.Web-Based Enterprise Services (WEBES) is a service tool that provides real-time diagnosis of hardware events ranging from single errors (or faults) to multiple event correlation and complex analysis. It is designed to send notification only when events require a service action. WEBES must be installed to ensure proper alerts for your EVA products. You can use WEBES with HP ISEE remote service, or you can configure WEBES to send email notification only to a local account. The email option is also available when you use WEBES with ISEE. HP recommends that you check the HP web site for updates. You can download the latest WEBES kit from this location:https://support.hpe.com/hpesc/public/homeHP Configuration Collector (HPCC) version v1.02 should be installed and configured by HP to ensure regular monitoring of the EVA configuration. HP field personnel can install HPCC when they are called to perform the upgrade.EVA VCS Support MatrixVCS VersionSupport StatementCurrent StatusRecommendationVCS v3.025No longer supportedNo longer supportedUpgrade to v3.100 immediatelyVCS v3.028End of Engineering Support (December 31, 2007)Supported but lacking latest availability and feature enhancementsUpgrade to v3.100 immediatelyVCS v3.100Latest supported version.Software moves to critical bug fix mode only (December 31, 2007)Available nowCustomer Self Upgrade (CSU) capabilityRequired for:No-migrate disk drive firmware upgrade capability
Customers with EVA3000/5000 storage systems currently running VCS v3.028 who have experienced any fault management issue as described in this document or who want to take advantage of the functionality listed in this document should install version v3.100.
Anyone wanting to take advantage of the enhancements or functionality in this release should update to it. For more information on the EVA, see the Technical Documentation which can be found at the following locations:http://h18006.www1.hp.com/products/storageworks/softwaredrivers/enterprise/index.html?jumpid=reg_R1002_USENWarranty ClarificationCustomers are advised to keep their SAN up-to-date to ensure the supportability and latest fixes are incorporated. Other SAN components that might be required to be upgraded have their own warranty policies. Please refer to the documentation for those products for this information.RECEIVE PROACTIVE UPDATES:Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisory
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.