HP is pleased to announce a new version of the Web-Based Enterprise Services (WEBES) v4.5. HP recommends that all customers using WEBES to manage the HP StorageWorks Enterprise Virtual Array (EVA) upgrade to v4.5.HP strives to continually improve and enhance WEBES rules and diagnostics. As a result, it is important for customers to be using the most current version of WEBES. When connected to Instant Support Enterprise Edition (ISEE), the tools can be configured to transmit status information directly to HP Service Centers for proactive resolution of issues. Customers can also configure WEBES to a local notification source for monitoring the EVA.
WEBES v4.5 has been released for the following platforms only:Windows Pentium based systemsHP ProLiants with HP StorageWorks EVA Command ViewHP OpenView Storage Management Appliances, managing HP StorageWorks EVA systems listed in the System Event Analyzer (SEA) User Guide's Supported Products section in Chapter 1WEBES v4.5 supports the following EVA products:HP Storage Works EVA4000/6000/8000 products with XCS v6.000 and earlierHP Storage Works EVA3000/5000 with VCS v4.004 and/or v3.028 and earlierHP StorageWorks Command View EVA v6.x management software and earlier
New features and fixes in WEBES v4.5 for Windows Pentium include:Added a note in the full description field when an Event Log Collection (ELC) is sent with the report.Increased the number of ELC attachments by sending an ELC during any proactive disk drive failure and certain other disk failure reports.Enhanced Customer Self Repair (CSR) procedure information and added SML links.Added support for SNMP Service Type 3 Trap in a subset of WEBES call out reports.Added a note in the Field Replaceable Unit (FRU) field to indicate if a part needs to be Reduction of Hazardous Substances (RoHs) compliant.Improved analysis of a drive missing event (09 3E) when the drive has faulted.Enhanced disk drive check condition rules. Based on analysis of field data, the error threshold levels for numerous ASC/ASCQ values have been adjusted to more effectively predict drive failures.Important:If the Windows Application Event Log is not cleared, WEBES will scavenge and reproduce call outs for past service events after it has been installed. If service has recently been required, it is strongly recommended that this log be cleared before installing v4.5.Important:HP StorageWorks Command View EVA v6.x has new security features which require WEBES v4.5. Older versions of WEBES cannot monitor arrays managed by Command View EVA v6.x. Follow the procedures in Section 2.2 Installing WEBES (Installing WEBES on Windows) of the WEBES install guide to enable WEBES to receive log information to analyze.WEBES must be installed on the same operating system with HP Command View EVA software. WEBES requires Command View EVA to be installed on systems that manage HP StorageWorks EVAs. WEBES is customer upgradeable. Save the self–extracting install copy of WEBES v4.5 from the web site listed below. Once saved on the management server, run the installer and follow the instructions provided.If any pre–release build of WEBES v4.5 has been installed, this must be replaced with the official final kit build of v4.5. The existing WEBES must be uninstalled before installing the final kit. Do not attempt to install the final kit without first uninstalling the earlier kit. Upgrades from one WEBES version to another version within two version numbers are supported, but cannot be upgraded from one build to another build of the same WEBES version.If an earlier version of WEBES has been installed, and a directory other than the default%SystemDrive%\Program Files\Hewlett–Packard\svctoolshas been chosen for the installation, do not upgrade WEBES to v4.5. Instead, uninstall the older version of WEBES and then install v4.5. Please note that when the older version of WEBES is uninstalled there is a pop–up message indicating that the configuration data is stored under a folder. It will ask if this is to be saved for future installations of WEBES.HP recommends that YES be chosen.If NO is chosen, the configuration information will need to be reentered when v4.5 is installed.If an earlier version of WEBES was installed in the default directory%SystemDrive%\Program Files\Hewlett–Packard\svctools, then the upgrade to WEBES v4.5 can be completed without issue.Web download sitehttp://www.hp.com/services/webes/NOTE:that the WEBES v4.5 kit that will be downloaded is Build 290. This build has been released to address an install issue that was seen with an earlier build.INSTALLING OR UPGRADING INSTANT SUPPORT ENTERPRISE EDITION (ISEE) CLIENT AFTER INSTALLING OR UPGRADING WEBESIf WEBES is installed or upgraded, followed by an installation or upgrade to ISEE Client software on the same system, follow the steps listed below after the ISEE install or upgrade, to allow SEA to send EVA collections to HP via ISEE:In a command prompt window, "cd" to the directory containing the script which raises the limit, which can vary depending on where you installed WEBES. Example:cd C:\Program Files\Hewlett–Packard\svctools\specific\ca\configExecute the following command: cscript changeFileSizeLimit.js 10 This will change the file size limit to 10 MB, which is enough for SEA's purposes (10 is the maximum).A log file is created in the current directory namedchangeISEEFileLimit.log. Open this log file in an editor such asNotepadto see whether the script executed successfully or not.RECEIVE PROACTIVE UPDATES:Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HP Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:http://www.hp.com/go/myadvisory
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.