A BF (Fatal) error code combined with a flapping, whirring or ratcheting sound on a HP StorageWorks 1/8 SDLT 320 Tape Autoloader is likely caused by a dropped drive leader, or possibly due to a tape hub that isn’t seated properly.
AA926A -- HP StorageWorks 1/8 SDLT 320 Tape Autoloader
Inspect the tape hub of the cartridge that was in the drive at the time of the failure. It should also be flush with the shell of the cartridge.If it is not flush, there may be an off-center circular scoring pattern on the hub. These two symptoms indicate that the cartridge didn’t correctly engage the tape hub with the drive hub. Test the cartridge further by pressing gently on the hub and determining if it returns back to its approximate original position. If it returns correctly, then the tape can be used again. If not, then the tape should not be used again.If the issue was NOT caused by the misaligned tape hub, the tape autoloader will mostly need to be exchanged due to a dropped drive tape leader, and all the cartridges used with the autoloader MUST also be inspected since damaged tapes can cause a healthy drive to drop a leader.Three tape problems that can cause a drive to drop a leader:Improper seating (clips should be fully retracted towards the left side of the opening)Bent or towed-in appearance on one or both clips, as per the diagram below.Bent tape leader pin that supports the clips on the tape.