The use of an incorrect account group name may cause HP StorageWorks Replication Solutions Manager (RSM) enabled host credential validation to fail. In the “Setting Credentials” section of HP StorageWorks Replication Solutions Manager installation guide, the instruction is to create the “hphaadmin” group for non-Windows host agent systems. This name is incorrect. The correct group name to use is “hphaadm”.If the group name “hphaadm” is not used, the server software cannot validate the group credentials and the system will not be added to HP Replication Solutions Manager as an enabled host.
HP StorageWorks Replication Solutions Manager installation guide (T3687-96049, February 2006)
Use the proper group name when creating the HP Storage Administrator “hphaadm” account group on non-Windows systems as noted in Description section above.