Document Release #Document Release DateRelease Details713-Jun-07Updated version support matrix to use Active/Inactive Terminology and set the Inactive date to March 31, 2008621-Mar-2007Extended expiration date, included information about EMU and HDD fw updates. Updated version support matrix526-Sep-2006Fix URL for HP SIM and updated the VCS support matrix412-Jul-2006This document was updated to ensure its availability on the appropriate Business Support Center product pages.10-Dec-2005This document was updated to ensure its availability on the appropriate Business Support Center product pagesAdded support for Solaris 10. See Operating system & HBA support changes sectionAlso, Document ID has changed from OI050624_CW01 to c00584762314-Sep-2005Removed Solaris 10 from supported Operating Systems222-Aug-2005Minor text edits121-Aug-2005Note on unsupported Operating Systems in Scope section. Link to Continuous Access, Business Copy, and Replication Solutions Manager matrices in Scope section015-Aug-2005Original Document ReleaseHP StorageWorks Division is pleased to announce the availability of Virtual Controller Software (VCS) v3.028. This version is a general availability maintenance release version for EVA3000 and EVA5000 storage systems. For full instructions forupdating product software,please refer to Updating Product Software, document 5697-5397.NOTE: VCS v3.028 has been updated to include changes to the Environmental Monitoring Unit (EMU) firmware intended to address instances of unsuccessful loop recovery which occur as a result of fibre channel disk drives that exhibit loop disruptor behavior. Changes made by this version of VCS v3.028 are limited are to the EMU and another hardware component within the controller known as the Cabinet Bus Interface Chip (CBIC). There are no functional changes to the VCS v3.028 controller operational firmware included in this update. The changes to the EMU firmware and CBIC programming are identified in theHP StorageWorks Enterprise Virtual Array 3000/5000 VCS 3.028 EMU update code releasenotes document.The VCS v3.028 update also includes an updated v3.028 HDD Superfile which contains updated disk drive firmware. The updated firmware is intended to address the behavior of the affected drives and enable them to better recover from loop disruption issues and capture data about the drive behavior. The changes to the HDD Superfile firmware are identified in theHP StorageWorks Enterprise Virtual Array 3000/5000 VCS 3.028 EMU update coderelease notes document.
Features and Issues Resolved in v3.028Operating system & HBA support changesSupport has been added for the following operating systems since the release of v3.025:Windows 2003 with SP1Windows 2003 Extended Systems (X64)Linux Red Hat Advanced Server 4.0OpenVMS 8.2 (IA64 & Alpha servers)VMware ESX/GSX/WSX 2.5.1IBM AIX 5.3Solaris 10NOTE: Secure Path v3.0D SP1 is required for Solaris 10. To download the Secure Path v3.0d for Sun Solaris Software Update go to:Secure Path v3.0DSupport has been added for the following HBA:Re-instated IBM 1GB Cambex HBA support with Secure Path v2.0D SP2 with IBM AIX v5.1 and v5.2Support is no longer provided for the following operating systems:Windows NT 4.0Netware 6.0IBM AIX 4.3.3OpenVMS 7.2-2, 7.3-1NOTE: Customers operating the EVA with operating systems that are not supported by HP StorageWorks may experience issues. Since testing has not occurred with these operating system environments, the range of these issues is unknown. Root cause analysis for issues found in these unsupported operating system environments will not be provided.Fault Management and Diagnostic EnhancementsAdded event improvements to help maintain the array, and to assist support personnel in diagnosing issues quicker and more accurately. Improvements made within handling of logged events to increase system availability.General EnhancementsResolved the issue where a large host data transfer and simultaneous SCSI reservation change caused a low memory access controller restart. Changed EVAPerf performance data so it accurately represent hosts LUNs for the correct Vdisk. Corrected management of the drive firmware upgrade process where a disk could not be code loaded because the firmware image is not available. Corrected a VCS issue so that HP can now support Continuous Access EVA site failovers between VCS v3.020 and v3.028 during a one week upgrade window.Resolved an issue that prevented snapshot units from entering an overcommit state due to one or more disk drive failures. This issue affected snapshots or snapclones of any raid type with parent luns of any raid type. This could result in massive workload slowdowns and other sluggish behavior such as reconstruction taking a long time.Online Upgrades for System SoftwareHP supports performing Virtual Controller Software (VCS) firmware upgrades for the EVA storage arrays while applications and servers remain online. Successful online firmware updates require proper implementation of the EVA array, as well as appropriate I/O timeout parameters and other settings for application, clustering, HBA, and multipathing.There are also important considerations regarding the I/O load on the EVA during the firmware upgrade process. Finally, there are times when HP will notify a customer that planned application downtime may be required in order to complete a VCS firmware upgrade if multipathing software, HBA firmware, or management software also needs to be upgraded at the same time. For more information please refer to theCustomer Notice Enterprise Virtual Array 3000/5000 Online Upgrade, in a Microsoft Windows Environment, Best Practices(CN0745W) at the following URL:https://support.hpe.com/hpesc/public/docDisplay?docId=PSD_CN074HP Systems Insight ManagerHP Systems Insight Manager (SIM) is enclosed as an accessory with all StorageWorks arrays. HP SIM is the foundation for HP's unified server-storage strategy -- it is packaged as a no-cost, customer installable management application and is derived from the heritage of Compaq Insight Manager, HP Toptools, and HP Servicecontrol. HP SIM runs on HP Windows, Linux, and HP-UX and provides discovery and identification, fault management, security administration, asset reporting, and centralized configuration management across heterogeneous servers, storage and infrastructure. HP SIM is easily extensible, integrating other HP management products and value-add plug-ins such as the ProLiant Essentials, Integrity Essentials, and Server Essentials.HP SIM relies on industry standards like SMI-S, SNMP, SSH, WBEM, and WMI to detect and report heterogeneous device attributes. HP SIM may also be configured to launch array specific applications for configuration, reporting and replication. For more information on HP Systems Insight Manager see:http://h18013.www1.hp.com/products/servers/management/hpsim/EVA Remote Support ToolsHP recommends that Instant Support Enterprise Edition (ISEE) be installed with the upgrade to VCS v3.028. This is a no-charge feature for any Enterprise Virtual Array while under warranty or service support. This tool enables self-monitoring and diagnosis. ISEE can significantly reduce the time required to isolate and correct issues. As required by customers’ site constraints, the tool can be configured to transmit status information directly to an HP service center for proactive issue resolution or to a customer contact for monitoring.Web-Based Enterprise Services (WEBES) is a service tool that provides real-time diagnosis of hardware events ranging from single errors (or faults) to multiple event correlation and complex analysis. It is designed to send notification only when events require a service action. WEBES must be installed to ensure proper alerts for your EVA products. You can use WEBES with HP ISEE remote service, or you can configure WEBES to send email notification only to a local account. The email option is also available when you use WEBES with ISEE. HP recommends that you check the HP web site for updates. You can download the latest WEBES kit from this location:https://support.hpe.com/hpesc/public/homeHP ISEE Configuration Collector for EVA (HP ISEE CC for EVA) version v1.02 should be installed and configured by HP to ensure regular monitoring of the EVA configuration. HP field personnel can install HP ISEE CC when they are called to perform the upgrade.Improved disk drive error handlingIt is important for all EVA customers to stay current with EVA VCS code releases and disk drive firmware in order to ensure the highest level of array availability and reliability. HP continues to perform ongoing reliability testing and may identify new disk drive conditions that can lead to interruption of array operation. To assure the best EVA performance customers need to remain current on EVA VCS code and disk drive firmware updates.Our disk suppliers continually make significant improvements in disk drive operation. EVA provides a Code Load mechanism with VCS v3.020 and VCS v3.025 and VCS v3.028 that enables HP Services personnel to upgrade all disk firmware on a single EVA array in less than 20 minutes. Refer to the “HP StorageWorks Enterprise Virtual Array 3000/5000 VCS 3.028 EMU update code release notes” for details.The requirements detailed in theVCS/Storage System Software Upgrade Pathtable below supersede those of the previous documents.VCS VersionCurrent StatusRecommendationVCS v3.014Inactive VersionUpgrade to VCS v3.110 immediately.VCS v3.020Inactive VersionUpgrade to VCS v3.110 immediately.VCS v3.025Inactive VersionUpgrade to VCS v3.110 immediately.VCS v3.028Active VersionBecomes Inactive Version of firmware on March 31, 2008Upgrade to VCS v3.110.VCS v3.100Superseded by VCS v3.110Inactive VersionUpgrade to VCS v3.110.VCS v3.110Latest VersionActive VersionCustomer Self Upgrade (CSU) capabilityRequired for: No-migrate disk drive firmware upgrade capabilityFor the versions of Command View EVA, Continuous Access, Business Copy, and Replication Solutions Manager that support this release, refer to theHP StorageWorks EVA Software Compatibility Referenceon hp.com.
Anyone wanting to take advantage of any of the enhancements or functionality in this release should update to it.For more information on the EVA please refer to the Technical Documentation which can be found atwww.hp.com/go/eva5000Continuous Access or Business Copy customers requiring the use of long distance gateways should review the Continuous Access Release Notes prior to upgrading to v3.028 for any restrictions. The release notes are available at:http://h18006.www1.hp.com/products/storage/software/conaccesseva/index.html(Technical Documentation)Warranty ClarificationCustomers are advised to keep their SAN up-to-date to ensure the supportability and latest fixes are incorporated. Other SAN components that may be required to be upgraded have their own warranty policies. Please refer to the documentation for those products for this information.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.