Firmware updates may fail when HPE OneView versions earlier than 11.50 are used to update HPE Gen12 servers running HPE Integrated Lights-Out 7 (iLO 7) firmware version 1.20 or 1.21 with firmware bundles containing dual-signed components.When this issue occurs, the firmware update may fail with the following error:"The component file is invalid or lacks a valid signature. (SHFW_069)"For environments using VMware vSphere Lifecycle Manager (VLCM), cluster remediation may fail, and the associated HPE OneView server profile may remain in the "Pending External Action" state.There is no additional impact to the server beyond the firmware update not completing.For additional technical details about the underlying iLO firmware issue, refer toHPE Customer Advisory a00163648en_us.
This issue affects all HPE Gen12 server models that meet the following conditions:iLO 7 firmware version 1.20 or 1.21 is installed.An HPE OneView version earlier than 11.50 is used to perform the firmware update.One of the following firmware bundles containing dual-signed components is being applied:Service Pack for ProLiant (SPP): Version 2026.09.00.00 or laterSynergy Service Pack (SSP): Version SY-2026.10.01 or laterThe issue is not limited to specific HPE Gen12 server models or configurations.
To prevent the firmware update failure, as a workaround, perform the following steps:Upgrade iLO 7 firmware to version 1.24 on the affected servers.Retry the firmware update using the applicable SPP or SSP.For environments using VLCM, rerun cluster remediation to complete the firmware update. No additional recovery steps are required.This issue is addressed inHPE OneView version 11.50 and later. If the updated HPE OneView version is not available in the environment, use the workaround described above.For instructions to download and install the recommended iLO 7 firmware and for additional technical details, refer toHPE Customer Advisory a00163648en_us.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.