The HPE Integrated Lights-Out 6 (iLO 6) Integrated Management Log (IML) may report the following event on any HPE ProLiant Compute XD685 system:"Failed to set Power Supply shutdown delay: Perform a delayed AC power cycle."This event indicates that iLO was unable to configure the shutdown delay setting on the power supply.Conditions experienced:The event is recorded in the iLO Integrated Management Log (IML).The event may reoccur after one or more delayed AC power-cycles.Repeated occurrences may indicate a potential power supply failure.
Any HPE ProLiant Compute XD685 system running HPE Integrated Lights-Out 6 (iLO 6).
If the event"Failed to set Power Supply shutdown delay: Perform a delayed AC power-cycle"is observed in the iLO Integrated Management Log (IML), perform the following steps:Power off the server.Physically disconnect all AC power cables from the server.Wait at least4 minutes to allow residual power to drain.Reconnect all AC power cables to the server.Power on the server and check the iLO IML to verify whether the event has cleared up.IMPORTANTIf the event occurs repeatedly after performing the recommended delayed AC power-cycle, perform the following steps:Collect an Active Health System (AHS) log from the affected HPE ProLiant Compute XD685 server.Contact HPE Support and provide the AHS log for further analysis.Contact your localcountry HPE Customer Supportor log a case via theHPE Support Center.HPE Support will analyze the Active Health System (AHS) logs to identify if there is an affected power supply, and to determine if a replacement is required.
Operating Systems Affected:OS Independent
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.