SUMMARY:On L25.09 RVU, Non-threaded applications or Posix User Thread applications using OSS system call select() or Guardian APIs FILE_COMPLETE_SET_() and FILE_COMPLETE_ family of procedures on an OSS file may cause CPU halt %5100 under certain conditions.DETAILED DESCRIPTION:Non-threaded applications or Posix User Thread applications working with OSS files might cause CPU halt %5100 under the following conditions.A non-KLT (Kernel Level Thread) non-threaded application opens an OSS file and then performs a select operation or enables completion through FILE_COMPLETE_SET, or a PUT application opens an OSS file and performs a blocking I/O.An OSS operation is attempted using an invalid file descriptor, or the application attempts to open an OSS file after reaching the maximum open-file limit.The application terminates abruptly.ORA non-KLT non-threaded application opens an OSS file and enables it for completion through FILE_COMPLETE_SET_.An OSS operation or FILE_COMPLETE_SET_ is attempted using an invalid file descriptor, or the application attempts to open an OSS file after reaching the maximum open-file limit.One of the FILE_COMPLETE_ family of procedures is called.ORFrom a PUT( Posix User Thread) application, thread-1 opens an OSS file and performs a blocking I/O.Thread-2 performs an OSS operation using an invalid file descriptor, or it attempts to open an OSS file after reaching the maximum open-file limit.The OSS file on which thread-1 is blocking becomes ready.Likelihood: Likely under the stated conditions
Affected Software Product Revision(s) (SPR(s)):T9055L06Release Version Updates (RVUs) containing the affected SPR(s):L25.09.00 L25.09.01 L25.09.02
RVUs containing final fix:Next RVU(R)PREVENTIVE ACTION:Workaround:NoneFix:Install the appropriate SPR for T9055 as shown below, based on your release version.Install the following SPR:T9055L06^ALF( Enscribe File System ) - already availableThis SPR already is present in these RVUs:NoneThis SPR is usable with the following RVUs:L25.09.00 L25.09.01 L25.09.02Installation impact:SYSGEN and system load required.You can check with the GNSC for applicability of the above SPR(s) to RVURs released since publication of this Hotstuff.Please refer to the appropriate softdoc(s) for detailed SPR information, including installation instructions, superseded SPRs, and requisite SPR lists.Note: In some cases, requisite SPRs might have greater installation impact than the SPR(s) described in this Hotstuff.
Operating Systems Affected:Nonstop OS L25.09
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.