Loading...
Loading...
Firmware packages labeled Cray.XD225v.XD295v.Turin.xxxx firmware kits incorrectly state that they should not be installed on Genoa / Bergamo / Genoa-X / Turin processors.The Cray.XD225v.XD295v.Turin.xxxx firmware is supported on the new system board assembly MLB Part Number "ASSY P53835-003", Spare Part Number "P55794-002", with Genoa, Bergamo, Genoa-X, and Turin processors.The release notes for the kits should have stated the following:"If the node is using MLB PN: ASSY (P53835-001 / P53835-002) or FRU (P55794-001), do not upgrade to this version"For information and details on mixing and identifying the various system board revisions, refer to the following Customer Advisory:HPE Cray XD225v - Node Compatibility Issues May Occur Between Rev002 and Rev003 System Boards
Either of the following HPE Cray XD systems is affected:HPE Cray XD225v 1U Node Configure-to-order Server (P52183-B21)HPE Cray XD295v 2U Node Configure-to-order Server (P52184-B21)Affected firmware packages:Cray.XD225v.XD295v.Turin.BIOS.Linux Version 5.60Cray.XD225v.XD295v.Turin.BMC.Linux Version 5.60Cray.XD225v.XD295v.Turin.CPLD 5252Cray.XD225v.XD295v.MPS.VRD.Turin Version 4.05.0
Cray.XD225v.XD295v.Turin.xxxx firmware kits can be installed on system board assembly MLB Part Number "ASSY P53835-003", Spare Part Number "P55794-002", with Genoa, Bergamo, Genoa-X, and Turin processors.Future firmware kit release notes will be corrected.
Operating Systems Affected:Not Applicable