When SUSE Linux Enterprise Server (SLES) 16 is running on an HPE Synergy 480 Gen11/Gen12 Compute Module that boots from a Fibre Channel Boot LUN via any of the HPE Host Bus Adapters (HBAs)/HPE Converged Network Adapters (CNAs) listed in the Scope section below, performing an eFuse or power cycle reset may cause the operating system to report EXT4 filesystem errors and enter emergency mode.Typical error messages observed:EXT4-fs error (device dm-5): bad orphan inodeEXT4-fs error (device dm-5): Orphan file not empty on read-only fs.EXT4-fs (dm-5): mount failed
Any HPE Synergy 480 Gen11/Gen12 Compute Module running Suse Linux Enterprise Server 16 and configured with any of the following adapters:HPE Host Bus Adapters (HBA)HPE Synergy 5330C 32Gb Fibre Channel Host Bus Adapter (870828-B21)HPE Synergy 5331C 32Gb Fibre Channel Host Bus Adapter (P76653-B21)HPE Synergy 5830C 32Gb Fibre Channel Host Bus Adapter (777456-B21)HPE Synergy 7330C 64Gb Fibre Channel Host Bus Adapter (P68131-B21)HPE Network Adapters / Converged Network Adapters (CNA)HPE Synergy 4820C 10/20/25Gb Converged Network Adapter (876449-B21)HPE Synergy 6820C 25/50Gb Converged Network Adapter (P02054-B21)
As a workaround, perform any of the following preventive procedures:PROCEDURE 1: Add a kernel parameter to force filesystem check on bootAdd the following parameter to the kernel command line:fsck.mode=forceNOTE: This option forces a filesystem scan on every reboot, which may significantly increase boot time on systems with large file systems.ORPROCEDURE 2: Convert the filesystem to btrfsConvert the existing EXT4 filesystem tobtrfs. Instructions are available atConvert - brtfs-convert tool instructionsNOTE: Back up all important data before proceeding with the conversion.ORPROCEDURE 3: Reinstall SLES 16 with the default btrfs filesystemPerform a fresh installation of SLES 16, selecting the defaultbtrfsfilesystem option during setup.RECOVERY OPTIONSIf the Operating System has already entered emergency mode, perform either of the following procedures to recover the system:PROCEDURE 1: Manually clear the orphan fileLog in as root when prompted.Execute the following command, replacing X with the appropriate device number (for example, dm-5):e2fsck -fp /dev/dm-XEnter exit to continue booting.ORPROCEDURE 2: Perform a cold bootPower off the system completely and power it back on. The Operating System should boot successfully after a cold boot.The advisory will be updated when additional solutions become available.Disclaimer: One or more of the links above will take you outside the HPE website. HPE is not responsible for content outside of its domain.Revision HistoryDocument VersionRelease DateDetails2August 13, 2026Resolution section has been updated with new workarounds.Recovery procedures have been added to the Resolution section.HPE Synergy 480 Gen11 Compute Module has been added.The following HPE adapters have been added:HPE Host Bus AdaptersHPE Synergy 5330C 32Gb Fibre Channel Host Bus Adapter (870828-B21)HPE Synergy 5830C 32Gb Fibre Channel Host Bus Adapter (777456-B21)HPE Network Adapters (CNA)HPE Synergy 4820C 10/20/25Gb Converged Network Adapter (876449-B21)HPE Synergy 6820C 25/50Gb Converged Network Adapter (P02054-B21)1February 6, 2026Original Document Release.
Operating Systems Affected:SUSE Linux Enterprise Server 16
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.