On HPE Gen11 Systems, the Global Component Integrity and the Policy settings return to default configurations after updating HPE Integrated Lights-Out 6 (iLO 6) firmware v1.73 (or later).After updating to iLO 6 firmware v1.73 (or later), from any version earlier than iLO 6 firmware v1.73, the Global Component Integrity Settings Defaults to the following configuration:Global Component Integrity - DisabledComponent Integrity Policy - No Policy
Any HPE Gen11 system after updating to iLO 6 firmware v1.73 (or later).
After updating the iLO 6 firmware v1.73 (or later), re-configure the Global Component Integrity and Policy settings in iLO 6.This is targeted to be addressed in a future release of iLO 6 firmware. This advisory will be updated when additional information is available.