Rebuild does not start automatically after replacing HPE MR Gen11, Gen10 Plus, and Gen10 Storage Controllers with an existing set of HDDs/SSDs when the logical drive was degraded and one or more drives have failed on the original controller.
This issue applies to the following controllers:HPE MR Gen10 Plus and Gen11 controllersHPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller (P58335-B21)HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller (P47781-B21)HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller (P47789-B21)HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller (P74775-B21)HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller (P47777-B21)HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller (P47785-B21)HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P26279-B21)HPE MR416i-p Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller (P06367-B21)HPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26325-B21)HPE MR216i-p Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller (P26324-B21)HPE Smart Array MR Gen10 controllersHPE Smart Array P824i-p MR Gen10 12G SAS PCIe Controller
To prevent this issue, HPE recommends replacing MR controllers only when all volumes are optimal. Do not replace a controller if any volume is degraded or rebuilding; if you do replace it, manually start the array rebuild on the new controller via the "Elements Actions" section at the right of the HPE MR Storage Administrator (MRSA) window to bring the volume to optimal.To start a manual rebuild on the new controller, perform the following steps in the "Elements Actions" section on the right side of the HPE MR Storage Administrator (MRSA) window to manually start the array rebuild on the replacement drive.In theDrives>Unconfigured Good Drivessection, select the replacement drive and clickAssign Dedicated Spare.The Arrays dialog will display. Select the degraded array to assign the Dedicated Spare.The replacement drive is now changed to "Configured, status Rebuild."Once the rebuild is complete, the disk will appear as "Online" and the array as "optimal."
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.