After an HPE NS204i device firmware update to version 1.2.14.1022 or later, during normal operation of HPE Gen11/Gen12 Servers, the following messages may display randomly on the HPE Integrated Management Log (IML) or HPE Integrated Lights-Out (iLO) User Interface (UI):"01/12/202615:50:31: Slot=19 Storage - Drive at Port 1 Box 0 Bay 0 status changed to Failed01/12/202615:50:36: Slot=19 Storage - Drive at Port 1 Box 0 Bay 0 status changed to Ok"OR"01/12/202608:23:19: Slot=19 Storage - Drive at Port 1 Box 0 Bay 0 status changed to Failed01/12/202608:23:19: Slot=19 Storage - Drive at Port 1 Box 0 Bay 0 status changed to predictive failure01/12/202608:23:24: Slot=19 Storage - Drive at Port 1 Box 0 Bay 0 status changed to Ok"The drive failure and OK messages are transient and reported within 10 seconds of each other.iLO 7 User Interface ExampleWhen this issue occurs, similar drive state and health can be found on iLO 5/iLO 6.After the issue occurs, HPE iLO Insight Remote Support (IRS) will automatically open or log tickets/case with HPE. When OneView is configured on the system, OneView will manage any server alerts that are generated.Note: There is no functional impact for the device models (shown in the Scope section below).
Any HPE NVMe Solid State Drives (SSDs) for the models listed below:HPE NS204i-u Gen11 NVMe Hot Plug Boot Optimized Storage DeviceHPE NS204i-u v2 480GB NVMe Hot Plug Boot Optimized Storage DeviceHPE NS204i-u v2 960GB NVMe Hot Plug Boot Optimized Storage DeviceHPE NS204i-u v2 960GB NVMe SED Hot Plug Boot Optimized Storage DeviceHPE Synergy NS204i-d Gen11 NVMe Boot Storage DeviceHPE Synergy NS204i-d v2 M.2 Boot Storage Device
The messages may continue to appear intermittently for affected models of the NS204i devices (shown above), however, there is no functional impact for the device models.This false reporting issue is mitigated by updating the NS204i NVMe devices to firmware version 1.2.14.1026 found inFirmware Package - HPE Gen12 Boot Controller NS204i-u, HPE Gen11 Boot Controller NS204i-u, NS204i-d and HPE Gen10 Plus Boot Controller NS204i-p, NS204i-d, NS204i-t, NS204i-r.Document VersionRelease DateDetails2March 04, 2026Updated the Resolution with the permanent fix.1January 16, 2026Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.