The "Enabling Drive Security" section of theHPE MR Storage Administrator User Guidestates the following:Pause for password at boot timeandEnforce strong password security– If you select thePause for password at boot time, you are prompted to provide the password each time you restart your server.However, once the instructions to select "Pause for password boot time," are followed, there is no prompt to request a password each time the server resets.
This issue affects the following HPE MR Controllers:HPE Compute MR ControllersHPE MR216i-a Gen10 Plus x16 Lanes without Cache NVMe/SAS 12G Controller - P26325-B21HPE MR216i-o Gen11 x16 Lanes without Cache OCP SPDM Storage Controller - P47789-B21HPE MR216i-p Gen11 x16 Lanes without Cache PCI SPDM Plug-in Storage Controller - P47785-B21HPE MR408i-o Gen11 x8 Lanes 4GB Cache OCP SPDM Storage Controller - P58335-B21HPE MR408i-p Gen11 x8 Lanes 4GB Cache PCI SPDM Plug-in Storage Controller - P74775-B21HPE MR416i-a Gen10 Plus x16 Lanes 4GB Cache NVMe/SAS 12G Controller - P26279-B21HPE MR416i-o Gen11 x16 Lanes 8GB Cache OCP SPDM Storage Controller - P47781-B21HPE MR416i-p Gen11 x16 Lanes 8GB Cache PCI SPDM Plug-in Storage Controller - P47777-B21
If "Pause for password at boot time" is selected, then each time the system resets, do the following:PressF9 > System Utilities > System Configuration > BIOS/Platform Configuration (RBSU)and locate the "Enter Boot Time Password" in theController Settingspage.Enter the password and clickApply Change. Any Self-Encrypted Drive (SED) that is listed under the controller can now be configured.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.