Loading...
Loading...
When applying an HPE OneView profile with network connections that uses virtual MAC addressing, the virtual MAC address may not be applied. This causes the physical MAC to be used instead of the virtual MAC. As a result, the virtual address displayed in the server profile will not match what is displayed in the Server Hardware or Network Adapter page in the HPE Integrated Lights-Out (iLO).In some cases, the network connectivity may not function as expected. This can occur if the MAC reservations are used for PXE boot, or if the host OS uses network bonding.The examples below detail what will be found in the OneView Server Profile, OneView Server Hardware and Network Adapter page in Integrated Lights-Out (iLO):OneView Sever ProfileOneView Server HardwareNetwork Adapter in iLO
HPE OneView 10.20 or earlier with HPE Synergy Gen12 Compute Module and HPE Synergy 6310C 25/50Gb Ethernet Adapter.
This issue is fixed by updating toHPE OneView 11.01or later.ORUpdate to HPE Integrated Lights-Out 7 (iLO 7) firmware version 1.19 or later by usingOnline ROM Flash Firmware Package - HPE Integrated Lights-Out 7.As a workaround, re-apply the profile until the virtual MAC is set correctly. This may require multiple profile re-apply attempts.Document VersionRelease DateDetails2February 18, 2026Updated the Resolution with the permanent fixes1November 25, 2025Original Document Release.
Operating Systems Affected:Not Applicable