On any HPE Gen12 platform configured with any of the HPE Intel E810-based / E830-based network adapters listed in the Scope section below; the "State" on the iLO7 web GUI is displayed as "Starting" instead of "Enabled" when the network adapter driver is not loaded.This displayed info can generate some confusion; however, there is no impact on the functionality of the network adapters.Once either the Inbox driver or the Out-of-Box (OOB) driver is loaded, the "State" will change to "Enabled".
Any HPE Gen12 platform running a Linux operating system, and configured with any of the following HPE Intel E810-based / E830-based network adapters:Intel E810-2CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE (P41611-B21)Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 Adapter for HPE (P21112-B21)Intel E810-CQDA2 Ethernet 100Gb 2-port QSFP28 OCP3 Adapter for HPE (P22767-B21)Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 Adapter for HPE (P08443-B21)Intel E810-XXVDA2 Ethernet 10/25Gb 2-port SFP28 OCP3 Adapter for HPE (P10106-B21)Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 Adapter for HPE (P08458-B21)Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Adapter for HPE (P41636-B21)Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 MCLK Non-GNSS Adapter for HPE (P75068-B21)Intel E810-XXVDA4 Ethernet 10/25Gb 4-port SFP28 OCP3 Adapter for HPE (P41614-B21)Intel E830 Ethernet 10/25Gb 8-port SFP28 OCP3 Adapter for HPE (P84529-B21)
This condition is expected and the system functions normally; therefore, a fix is not required.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.