For any HPE Cray XD670, System ROM version 2.00 (or later) correctly reports the Bus, Device, Function, and the link speed between the following devices:HPE Cray XD670 CMT4034 PCIe M.2 Pass-Through Adapter for HPC (P60995-B21)Samsung MZ1L23T8HBLA-00A07 PM9A3 3.84TB PCI-E Gen4 x4 M.2 SSDsThe Samsung MZ1L23T8HBLA-00A07 PM9A3 is designed to run at the maximum speed of Gen4. The adapter mentioned above runs at the maximum speed of Gen3. When the Samsung MZ1L23T8HBLA-00A07 PM9A3 is connected to a slower controller, the SSD will run at Gen3 speed.System ROM versions prior to 2.00 reported the Bus, Device, and Function as 0000:be:00.0, 0000:bf:00.0, 0000:c0:00.0, and 0000:c1:00.0. Additionally, the link speed was incorrectly reported as 16GT/s (Gen4).System ROM version 2.00 (or later) correctly reports the following:
In the scenario described above, any HPE Cray XD670 configured with:HPE Cray XD670 CMT4034 PCIe M.2 Pass-Through Adapter for HPC (P60995-B21)Samsung MZ1L23T8HBLA-00A07 PM9A3 3.84TB PCI-E Gen4 x4 M.2 SSDs
To avoid this issue, update the System ROM to version2.00(or later).