After a liquid cooled server is automatically shut down due to a coolant leak being detected, the server will not allow a Power On if this leak still exists. In addition, HPE OneView will display an incorrect reason in the message for the server that is not powering on:This issue can be seen with an HPE OneView appliance that is managing a server with a Close-Loop Liquid Cooling (CLLC) heatsink and with HPE Integrated Lights-Out 6 (iLO 6) firmware version 1.59 or later, or any iLO 7 firmware versions.
Any HPE server with an HPE OneView appliance that manages a liquid cooled server using Close-Loop Liquid Cooling (CLLC) heatsink, and with HPE Integrated Lights-Out 6 (iLO 6) firmware version 1.59 or later, or any integrated Lights-Out 7 (iLO 7) firmware versions.
This message issue is resolved by updating toHPE OneView 10.20or later. A coolant leak message will be indicated if a leak is detected.The server will power on after the CLLC leakage has been fixed.Document VersionRelease DateDetails2April 03, 2026Updated the Resolution with the permanent fix.1July 31, 2025Original Document Release.
Operating Systems Affected:Not Applicable