A ProLiant Compute DL320 Gen12 server running a System ROM version earlier than 1.32 may experience a CPU fault issue during Power-On Self-Test (POST):‘Server Critical Fault (Service Information: CPU Thermal Fault, Processor(Intel), Processor 1 (80h)) ACTION: Gather Active Health System logs and create a support case.’This issue may occur on high density systems, such as those configured with 96GB DIMMs or higher (i.e., 96GB, 125GB, 256GB) in all 16 slots, in which the boot times may reach 30 minutes or more.
HPE ProLiant Compute DL320 Gen12 server running a System ROM version earlier than 1.32.Note that the ProLiant Compute DL340 Gen12 server is not affected by this issue.
This issue has been fixed with System ROM version 1.32, available at the following link:ROM Flash Firmware Package - HPE ProLiant Compute DL320/DL340 Gen12 (U71) ServersNote: To ensure that you have selected the latest version of the firmware/driver, click the Revision History tab to check if a new version of the firmware/driver is available. For more important information, review the Release Notes tab.
Operating Systems Affected:Not Applicable